KunLun Mission Critical Server V100R001 CMC Alarm Handling 09

This document describes KunLun 9016 and 9032 alarms in the CMC, in terms of their meanings, impact on the system, possible causes, and handling suggestions.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-37000011 Incorrect NI Cable Connection

ALM-37000011 Incorrect NI Cable Connection

Description

Alarm message:

Incorrect NI cable connection

Attribute

Alarm ID

Alarm Severity

Auto Clear

37000011

Major

Yes

Parameters

Name

Meaning

Alarm Severity

Indicates the alarm severity.

Alarm Source

Indicates the alarm source.

Subject

Indicates the event body for which an alarm is generated.

Time

Indicates the time when an alarm is generated.

Description

Provides an alarm description.

Event Code

Indicates the event code of an alarm.

Impact on the System

The service system cannot be powered on.

Possible Causes

A node interconnect (NI) cable is not connected or not properly connected to the basic partition unit (BPU).

Procedure

  1. Check whether an NI cable is connected to the BPU. For details, see the KunLun 90xx V100R001 User Guide.

  2. Connect an NI cable to the BPU. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 3.

  3. Check whether the NI cable is properly connected to the BPU.

  4. Remove and reconnect the NI cable. (For details, see the KunLun 90xx V100R001 User Guide.) Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 5.

  5. Contact Huawei technical support.

Clearing

After the fault is rectified, the system automatically clears the alarm.