This document describes KunLun 9016 and 9032 alarms in the CMC, in terms of their meanings, impact on the system, possible causes, and handling suggestions.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-37000015 Standby CMC Not Detected

ALM-37000015 Standby CMC Not Detected

Description

Alarm message:

Standby CMC not detected

Attribute

Alarm ID

Alarm Severity

Auto Clear

37000015

Major

Yes

Parameters

Name

Meaning

Alarm Severity

Indicates the alarm severity.

Alarm Source

Indicates the alarm source.

Subject

Indicates the event body for which an alarm is generated.

Time

Indicates the time when an alarm is generated.

Description

Provides an alarm description.

Event Code

Indicates the event code of an alarm.

Impact on the System

Central management enclosure (CME) reliability is reduced.

Possible Causes

  • The standby CMC is not installed.
  • The standby CMC is not properly installed.

Procedure

  1. Check whether the standby CMC is installed.

  2. Install the standby CMC. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 3.

  3. Remove and reinstall the standby CMC without affecting services (The CMC on which the ATC indicator is off is standby). Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 4.

  4. Contact Huawei technical support.

Clearing

After the fault is rectified, the system automatically clears the alarm.