KunLun Mission Critical Server V100R001 CMC Alarm Handling 09

This document describes KunLun 9016 and 9032 alarms in the CMC, in terms of their meanings, impact on the system, possible causes, and handling suggestions.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-3E000017 Failed to Obtain the PCIe Switch Temperature

ALM-3E000017 Failed to Obtain the PCIe Switch Temperature

Description

Alarm message:

Failed to obtain data of the %1 PCIe switch %2 temperature. 

Attribute

Alarm ID

Alarm Severity

Auto Clear

3E000017

Minor

Yes

Parameters

Name

Meaning

Alarm Severity

Indicates the alarm severity.

Alarm Source

Indicates the alarm source.

Subject

Indicates the event body for which an alarm is generated.

Time

Indicates the time when an alarm is generated.

Description

Provides an alarm description.

Event Code

Indicates the event code of an alarm.

Impact on the System

The temperature cannot be properly monitored and alarms cannot be sent promptly if any temperature exceptions occur.

Possible Causes

The management subsystem is in an abnormal state.

Procedure

  1. Restart iBMC when the system is powered on. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 2.

  2. Power off the server and reconnect the power cable. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 3.

  3. Power off the server and reinstall the board. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 4.

  4. Contact Huawei technical support.