Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-17000033 FPGA DDR3 Fault

ALM-17000033 FPGA DDR3 Fault

Description

Alarm message:

FPGA DDR3 fault.

Attribute

Alarm ID

Alarm Severity

Auto Clear

17000033

Major

Yes

Parameters

Name

Meaning

Alarm Severity

Indicates the alarm severity.

Alarm Source

Indicates the alarm source.

Subject

Indicates the event body for which an alarm is generated.

Time

Indicates the time when an alarm is generated.

Description

Provides an alarm description.

Event Code

Indicates the event code of an alarm.

Impact on the System

The KVM function, fan module and power supply unit (PSU) management function, and LCD function may be abnormal.

System Actions

None

Possible Causes

A DDR3 fault has occurred in the FPGA on the CMC.

Procedure

  1. Check whether the value of Subject in alarm locating parameters is CMC1 or CMC2.

  2. Remove and reinstall the CMC. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 3.

  3. Contact Huawei technical support.

Clearing

After the fault is rectified, the system automatically clears the alarm.