KunLun Mission Critical Server V100R001 CMC Alarm Handling 09

This document describes KunLun 9016 and 9032 alarms in the CMC, in terms of their meanings, impact on the system, possible causes, and handling suggestions.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-05000001 Power Supply to the Disk Backplane Failed

ALM-05000001 Power Supply to the Disk Backplane Failed

Description

Alarm message:

Power supply to [xxx] disk backplane failed. 

Attribute

Alarm ID

Alarm Severity

Auto Clear

05000001

Major

Yes

Parameters

Name

Meaning

Alarm Severity

Indicates the alarm severity.

Alarm Source

Indicates the alarm source.

Subject

Indicates the event body for which an alarm is generated.

Time

Indicates the time when an alarm is generated.

Description

Provides an alarm description.

Event Code

Indicates the event code of an alarm.

Impact on the System

The hard disk backplane cannot be used properly, which may result in service interruption.

Possible Causes

  • Cables are not properly connected to the hard disk backplane.
  • The hard disk backplane is faulty.

Procedure

  1. Restart the server. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 2.

  2. Reconnect cables to the hard disk backplane. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 3.

  3. Replace the hard disk backplane. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 4.

  4. Contact Huawei technical support.