KunLun Mission Critical Server V100R001 CMC Alarm Handling 09

This document describes KunLun 9016 and 9032 alarms in the CMC, in terms of their meanings, impact on the system, possible causes, and handling suggestions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-01000025 Memory Configuration Error

ALM-01000025 Memory Configuration Error

Description

Alarm message:

[Memory board #] xxx memory configuration error. Error code: 0xXXXX.
NOTE:

xxx indicates the DIMM silkscreen, or the CPU or channel number of the DIMM.

This alarm is generated when an incompatible DIMM is installed or when a DIMM is installed in an incorrect slot.

NOTE:

For details about DIMM configuration rules, see "Installing DIMMs" in the KunLun 90XX V100R001 User Guide.

The event type is: Memory

  1. If the mirroring function needs to be enabled or has been enabled in the BIOS, check whether the memory configuration after isolation meets the mirroring conditions. If not, the enabled memory mirroring function does not take effect.
  2. If the Lockstep mode needs to be enabled or has been enabled in the BIOS, check whether the memory configuration after isolation meets the Lockstep conditions. If not, the enabled Lockstep mode does not take effect.

Attribute

Alarm ID

Alarm Severity

Auto Clear

01000025

Critical

Yes

Parameters

Name

Meaning

Alarm Severity

Indicates the alarm severity.

Alarm Source

Indicates the alarm source.

Subject

Indicates the event body for which an alarm is generated.

Time

Indicates the time when an alarm is generated.

Description

Provides an alarm description.

Event Code

Indicates the event code of an alarm.

Impact on the System

The related DIMMs do not function properly, and server performance is affected.

Possible Causes

  • The DIMM installed is not compatible with the CPU.
  • DIMM installation positions are incorrect.

Procedure

  1. Power off the server and check the model of the DIMM for which the alarm is generated.
  2. Use the Huawei Server Compatibility Checker to check whether the DIMM model is compatible with the server.

  3. Check whether the DIMMs are installed in correct slots.

    For details about DIMM installation positions, see the KunLun 90XX V100R001 User Guide.

  4. Install the DIMMs in correct slots. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 6.

  5. Replace the DIMM with a compatible one and power on the server. Then check whether the alarm is cleared.

    For details about how to replace a DIMM, see the KunLun 90XX V100R001 User Guide.

    • If yes, no further action is required.
    • If no, go to Step 6.

  6. Contact Huawei technical support.