KunLun Mission Critical Server V100R001 CMC Alarm Handling 09

This document describes KunLun 9016 and 9032 alarms in the CMC, in terms of their meanings, impact on the system, possible causes, and handling suggestions.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Mapping Between FRUs and Sensors

Mapping Between FRUs and Sensors

Table A-1 describes the mapping between field replaceable units (FRUs) and sensors.

Table 8-1 Mapping between FRUs and sensors

FRU

Sensor

Monitoring ...

LPM

SYS 1.1V

Mainboard 1.1 V voltage

LPM

SYS 1.5V

Mainboard 1.5 V voltage

LPM

SYS 3.3V

Mainboard 3.3 V voltage

LPM

SYS 5V

Mainboard 5.0 V voltage

LPM

SYS 12V

Mainboard 12.0 V voltage

LPM

Standby 1.2V

Mainboard standby 1.2 V voltage

LPM

Standby 3.3V

Mainboard standby 3.3 V voltage

LPM

Standby 5V

Mainboard standby 5.0 V voltage

LPM

PCH Temp

PCH temperature

Back I/O module (BIO)

BIO Temp

Temperature at the air intake vent of a BIO

Indicator board

LedBoard Temp

Indicator board temperature

CPU board module

CpuBrd# Temp

CPU board module temperature

CPU board module

CPU# Core Rem

CPU core temperature

CPU board module

CPU# DTS

CPU DTS value

CPU board module

CPU# Prochot

CPU Prochot

Local partition management module (LPM)

Heartbeat

Heartbeats between LPM 1 and LPM 2

LPM

RTC Battery

RTC battery status

Front I/O module (FIO) or BIO

PCIE Status

PCIe status

LPM

ACPI State

ACPI states

LPM

SysFWProgress

Software processes and system startup errors

Indicator board

Power Button

Power button status (pressed or not)

LPM

SysRestart

System restart causes

LPM

Boot Error

Boot errors

LPM

Watchdog2

Watchdog

NA

Mngmnt Health

Health status of the management subsystem

LPM

UID Button

UID button status

LPM

PwrOk Sig. Drop

Voltage sag status

LPM

PwrOn TimeOut

Power-on timeout

CPU

CPU# Status

CPU status, including the installation status, thermtrip, CAT error, BIST, and disabled

Memory

CPU# Memory

Memory temperature status

CPU

CPU# QPI Link

Quick Path Interconnect (QPI) bus errors

CPU

CPU# Core

CPU core fault detection and isolation during BIOS startup

Memory board module (MBM)

MemBrd# DIMM

Status of DIMMs on an MBM

MBM

MemBrd# Mig

MBM migration status

RAID controller card

RAID# Status

RAID controller card status

RAID controller card

RAID# PCIE ERR

RAID controller card status reported by the fault diagnosis management (FDM) module

PCIe card

K1GPU$ Temp

Graphics processing unit (GPU) temperature

PCIe card

K2GPU$ Temp

GPU temperature

PCIe card

K10GPU$ Temp

GPU temperature

PCIe card

K20XGPU$ Temp

GPU temperature

PCIe card

K20CGPU$ Temp

GPU temperature

PCIe card

K20MGPU$ Temp

GPU temperature

PCIe card

M2090GPU$ Temp

GPU temperature

RAID controller card

RAID$ Temp

RAID controller card temperature

CPU board module

CPU$ MEM Temp

Temperature of DIMMs mapping to a CPU

Secure digital (SD) card 1

SD1 CARD

Health status of SD card 1

SD card 2

SD2 CARD

Health status of SD card 2

Card where SD cards 1 and 2 are installed

No SD Card

No SD card

Node controller module (NCM)

CXPCable #

Network interconnect (NI) cable lane drop or link down

NCM

CXPCable LNK#

NI cable link down

NC chip

NCBoard Stat1

NC chip bandwidth halving and error checking and correction (ECC) errors

NC chip

NCBoard Stat2

NC chip faults of the SEV2 level

NC chip

NC Chip Temp

NC chip temperature

NCM

NC In Temp

Temperature at the air intake vent of an NCM

NCM

NC Out Temp

Temperature at the air exhaust vent of an NCM

LPM

FRU Hot Swap

Hot swap status

Network interface card (NIC)

NIC# Status

NIC status

BIO

PCIE# Button

Hot swap button status (pressed or not)

LPM 2 sensor

LPM

Inlet Temp

Temperature at the air intake vent of a system compute enclosure (SCE)

Fan module

FAN# F Speed

Speed of a front fan

Fan module

FAN# R Speed

Speed of a rear fan

LPM

Power

Total input power

PSU

Power#

PSU input power

Fan module

FAN# F Status

Status of a front fan

Fan module

FAN# R Status

Status of a rear fan

Fan module

FAN# Presence

Fan module installation status

PSU

PS# Status

PSU fault status

PSU

PS# Fan Status

PSU fan status

PSU

PS# Temp Status

PSU high-temperature alarm

LPM 1 sensor

FIO

FioInlet M Temp

Temperature in the middle of the air intake vent of an FIO

FIO

FioInlet R Temp

Temperature on the right of the air intake vent of an FIO

FIO

FioInlet L Temp

Temperature on the left of the air intake vent of an FIO

FIO

HDDBkp9 Temp

Temperature nearby the hard disk backplane in slot 9

FIO

HDDBkp0 Temp

Temperature nearby the hard disk backplane in slot 0

FIO

HDDBkp2 Temp

Temperature nearby the hard disk backplane in slot 2

FIO

DISK#

Hard disk status

FIO

BkpB MISC Cable

Connection status of the MISC cable to hard disk backplane B

FIO

BkpC MISC Cable

Connection status of the MISC cable to hard disk backplane C

FIO

Bkp MISC Cable

Connection status of the MISC cable to the hard disk backplane

FIO

EXP# Status

Expander status