Recommended Device Models and Versions
Table 2-7 lists the recommended device models and versions for M-LAG networking.
Device Role |
Usage Scenario |
Recommended Device Model |
Recommended Version |
---|---|---|---|
Spine |
Medium- and large-scale network |
CE12800 (F series cards) |
V200R021C00SPC200 + latest patch |
CE16800 (G series and A series cards) |
V200R021C01SPC600 + V200R021SPH013 or a later patch |
||
CE16800 (P series and SAN series cards) |
V300R021C00SPC200 + latest patch |
||
Small-scale network |
CE8861EI |
V200R021C00SPC200 + latest patch |
|
CE8851 |
V300R021C00SPC200 + latest patch |
||
Server leaf |
10GE access |
CE6857EI/CE6857F (40GE/100GE uplink) |
V200R021C00SPC200 + latest patch |
CE6881/CE6881E (40GE/100GE uplink) |
V200R021C00SPC200 + V200R021SPH013 or a later patch |
||
CE6866-48S8CQ-P (200GE/100GE/40GE uplink) |
V300R021C00SPC200 + latest patch |
||
25GE access |
CE6865EI/CE6865E (40GE/100GE uplink) |
V200R021C00SPC200 + latest patch |
|
CE6863/CE6863E (40GE/100GE uplink) |
V200R021C00SPC200 + V200R021SPH013 or a later patch |
||
CE6866-48S8CQ-P (200GE/100GE/40GE uplink) |
V300R021C00SPC200 + latest patch |
||
40GE access |
CE8861EI (40GE/100GE uplink) |
V200R021C00SPC200 + latest patch |
|
100GE access |
CE8861EI (100GE uplink) |
V200R021C00SPC200 + latest patch |
|
CE8851 (100GE uplink) |
V300R021C00SPC200 + latest patch |
||
DCI leaf |
Small-scale DCI interconnection |
Same as that for server leaf nodes |
Same as that for server leaf nodes |
Large-scale DCI interconnection |
Same as that for spine nodes |
Same as that for spine nodes |
- You are not advised to use VSs to deploy M-LAG, because convergence is slow when a VS is reset or a peer-link fails.
- The two devices that set up an M-LAG cannot be configured with DHCP snooping.
- To enable the DHCP relay function, the function must be configured on both devices that set up an M-LAG.
- You are advised to deploy the DHCP server and NTP server on dedicated servers instead of on switches, because switches have limited CPU computing performance and high protocol running pressure.