LX1D2SFUX000-S9310X Switch Fabric Unit X
Version Mapping
Card Name |
S9300X Chassis |
---|---|
LX1D2SFUX000 |
S9310X chassis: supported in V200R010C00 and later versions S9300X-4, S9300X-8, and S9300X-12 chassis: not supported |
Introduction
The LX1D2SFUX000 can be installed in slots 11 and 12 of an S9310X chassis.
Functions
The LX1D2SFUX000 provides the data plane for the entire system. The data plane provides high-speed, non-blocking data channels for data switching between service modules.
The LX1D2SFUX000 consists of the following functional modules:
- Switching module: functions as the data plane and provides high-speed service channels for data switching.
- Local clock module: provides the working clock for the chips of the switching module, management module, and monitoring module on the LX1D2SFUX000.
- Power supply module: provides power supply for the LX1D2SFUX000.
Function |
Description |
---|---|
Basic function |
Core of data switching in the S9310X system. |
Clustering |
10GE or 40GE optical ports on the card can be used for cluster connection. |
Memory |
512 MB |
Flash |
64 MB |
Redundancy backup |
1+1 hot standby LX1D2SFUX000 cards in a chassis work in redundancy mode to improve system reliability. If one SFU fails, service traffic on this card will be switched to other SFUs to ensure uninterrupted services. |
Hot swapping |
Supported |
Usage Constraints
A chassis can have only one type of SFUs installed.
Indicators and Ports
1 |
Four 10GBASE SFP+ optical ports used for cluster connection between two chassis. They are multiplexed with the 40GE optical port. Either the 10GE ports or 40GE port can work at a time. By default, the four 10GBASE SFP+ optical port are used preferentially. |
2 |
One 40GBASE-X optical port used for cluster connection between two chassis. It is multiplexed with the four 10GE optical ports. Either the 40GE port or 10GE ports can work at a time. |
10GBASE SFP+ optical port
Table 7-46 lists the attributes of a 10GE BASE-SFP+ optical port.
Attribute |
Description |
---|---|
Connector type |
SFP+ |
Optical port attributes |
Depend on the SFP+ to SFP+ high-speed cable (1 m, 3 m, 5 m, 10 m), SFP+ optical module, or SFP+ optical cable used. For the optical modules supported by the card, see 10GE SFP+ Optical Modules (excluding the OSXD22N00) and 10GE-CWDM SFP+ Optical Modules. |
Applicable cable |
SFP+ optical module and LC optical fiber SFP+ high-speed copper cable SFP+ AOC cable |
40GBASE-X port
Table 7-47 lists attributes of a 40GBASE-X port.
Attribute |
Description |
---|---|
Connector type |
QSFP+ |
Optical attributes |
Depend on the QSFP+ optical module, QSFP+ to QSFP+ high-speed cable (1 m, 3 m, 5 m) or QSFP+ optical cable used. For the optical modules supported by the card and their attributes, see 40GE QSFP+ Optical Modules (excluding the QSFP-40G-SR-BD). |
Applicable cable |
QSFP+ optical module and LC optical fiber QSFP+ optical module and MPO optical fiber (MPO to MPO) QSFP+ high-speed copper cable (QSFP+ to QSFP+) QSFP+ AOC cable (QSFP+ to QSFP+) |
- One SFU can be connected to only one SFU in the other chassis. It cannot be connected to more than one SFU in the other chassis or to an SFU in the local chassis.
- Ports in group 1 on one SFU can only be connected to ports in group 1 on the other SFU. In addition, ports in group 1 must be connected sequentially based on their numbers. The port in group 2 on one SFU can only be connected to the port in group 2 on the other SFU.
- The two chassis must be connected by at least one cluster cable.
- Connect at least two cables on each SFU.
- Install at least two SFUs in each chassis.
Specifications
Item |
Description |
---|---|
Physical specifications |
|
Ordering Information
Card ordering information is subject to updates with product version upgrades. The ordering information provided in this manual is for reference only. To obtain the latest ordering information, contact Huawei switch distributors or Huawei local office.
Part Number |
Card Description |
Card Model |
---|---|---|
03031YWE |
S9310X Switch Fabric Unit X |
LX1D2SFUX000 |