LE1D2C02FEE0-2-Port 100GBASE-X Interface Card (EE, CFP)
Version Mapping
Card Name |
S9300X Chassis |
---|---|
LE1D2C02FEE0 |
S9310X chassis: supported in V200R010C00 and later versions S9300X-4, S9300X-8, and S9300X-12 chassis: not supported |
Introduction
The LE1D2C02FEE0 can be installed in:
- Slots 01 to 10 in an S9310X chassis.
Functions
Function |
Description |
---|---|
Basic functions |
Provides two 100GE optical ports for data transmission and switching. |
Distributed forwarding |
Performs concurrent data forwarding using a distributed data plane. |
Hot swapping |
Supported |
Indicators and Ports
Number |
Indicator |
Color |
Description |
---|---|---|---|
1 |
When a 100GE port is not split, this indicator shows the status of the 100GE port. |
Green |
Steady on: A link has been established on the 100GE port. Blinking: The 100GE port is transmitting and receiving data. |
2 |
When a 100GE port is split into two 40GE ports, indicators 0 and 1 show the status of the 40GE ports. |
Green |
When indicator 0 turns on, it shows the status of the first 40GE port derived from the 100GE port. When indicator 1 turns on, it shows the status of the second 40GE port. Steady on: A link has been established on the 40GE port. Blinking: The 40GE port is transmitting and receiving data. |
3 |
When a 100GE port is split into ten 10GE ports, indicators 0 to 9 show the status of the 10GE ports. |
Green |
When indicator 0 turns on, it shows the status of the first 10GE port derived from the 100GE port. Similarly, the other indicators turn on in sequence to show status of the rest of 10GE ports. Steady on: A link has been established on the 10GE port. Blinking: The 10GE port is transmitting and receiving data. |
4 |
RUN/ALM: running status indicator |
Green |
Steady on: The card is powered on. If the indicator is steady green for no more than 30 seconds, the CPU is being started. If the indicator is steady green for more than 30 seconds, the software is not running. Slow blinking: The card software is running properly. Fast blinking: The card software is starting. |
Red |
Steady on: The card has failed and the fault requires manual intervention. |
||
Yellow |
Steady on: The card is powered off. (For example, the card has been forcibly powered off using the power off command or is about to start.) |
1 |
Two 100GE optical ports |
100GE optical port
Table 7-861 lists the attributes of a 100GE optical port.
Attribute |
Description |
---|---|
Connector type |
CFP |
Optical port attributes |
Depend on the 40GE CFP Optical Modules and 100GE CFP Optical Modules used |
Applicable cable |
CFP optical module and LC optical fiber CFP optical module and MPO optical fiber (MPO-MPO, MPO-2*MPO, or MPO-10*DLC optical fiber) |
Specifications
Item |
Description |
---|---|
Physical specifications |
|
Environment specifications |
|
Ordering Information
Card ordering information is subject to updates with product version upgrades. The ordering information provided in this manual is for reference only. To obtain the latest ordering information, contact Huawei switch distributors or Huawei local office.
Part Number |
Card Description |
Card Model |
---|---|---|
03030XJJ |
2-port 100GBASE-X interface card (EE, CFP) |
LE1D2C02FEE0 |