LST3MPUEC000 (03034HXM-001: S9300X main control unit EC)
Overview
Item | Details |
---|---|
Description | S9300X main control unit EC |
Part Number | 03034HXM-001 |
Model | LST3MPUEC000 |
Appearance
Version Mapping
Product | Product Model | First Supported Version | IDs of available slots | Limitations |
---|---|---|---|---|
S9300X | S9300X-12 | V200R021C10SPC600 | 13–14 | If the card is used in V200R021C01, install V200R021SPH180 or a later patch. MPUs of different models cannot be used in the same chassis. After an active/standby switchover of MPUs is performed, fans in the chassis change to the intelligent speed adjustment mode. If you want the fans to run at a specific speed, run the set fan-speed command to set the fan speed after the switchover. |
S9300X | S9300X-4 | V200R021C10SPC600 | 05–06 | If the card is used in V200R021C01, install V200R021SPH180 or a later patch. MPUs of different models cannot be used in the same chassis. After an active/standby switchover of MPUs is performed, fans in the chassis change to the intelligent speed adjustment mode. If you want the fans to run at a specific speed, run the set fan-speed command to set the fan speed after the switchover. |
S9300X | S9300X-8 | V200R021C10SPC600 | 09–10 | If the card is used in V200R021C01, install V200R021SPH180 or a later patch. MPUs of different models cannot be used in the same chassis. After an active/standby switchover of MPUs is performed, fans in the chassis change to the intelligent speed adjustment mode. If you want the fans to run at a specific speed, run the set fan-speed command to set the fan speed after the switchover. |
Indicators and Buttons
1. CSS ID indicator |
2. CSS MASTER indicator |
3. USB indicator |
4. ACT indicator of the ETH port |
5. LINK indicator of the ETH port |
6. RST button |
7. ACT: active/standby status indicator |
8. RUN/ALM: running status indicator |
Silkscreen | Name | Color | Status | Description |
---|---|---|---|---|
1 2 3 4 5 6 7 8 | CSS ID indicator | Green | Steady on | There are eight CSS ID indicators on the panel, but only one is on at a time. CSS ID N is steady on: The CSS ID of the local chassis is N. |
Green | Off | All CSS ID indicators are off: The chassis is not running the CSS service. | ||
MASTER | CSS MASTER indicator | Green | Steady on | The MPU is the master MPU of the CSS. |
Green | Off | The MPU is not the master MPU of the CSS. | ||
USB | USB indicator | Green | Steady on | USB-based deployment of the card has been completed. |
Green | Fast blinking | The card is reading data from a USB flash drive. | ||
Yellow | Steady on | The card has finished reading data from the USB flash drive. You can remove the USB flash drive now. | ||
Red | Steady on | The card fails to connect to the network management system (NMS) or fails to register with the NMS. | ||
Red | Fast blinking | An error has occurred when the card is executing the configuration file or reading data from the USB flash drive. | ||
- | Off | No USB flash drive is connected to the card, the USB port on the card is damaged, or the indicator is damaged. | ||
ETH ACT | ACT indicator of the ETH port | Yellow | Blinking | The port is transmitting and receiving data. |
ETH LINK | LINK indicator of the ETH port | Green | Steady on | A link has been established on the port. |
ACT | Active/standby status indicator | Green | Steady on | The card is the active MPU of the switch. When two chassis set up a cluster: Steady on: The card is the active MPU of the cluster. |
Green | Off | The card is the standby MPU of the switch. When two chassis set up a cluster: off: The card is the cold standby MPU of the cluster. |
||
Green | Blinking | When two chassis set up a cluster: Blinking: The card is the hot standby MPU of the cluster. |
||
RUN/ALM | Running status indicator | Green | Steady on | The card is powered on. If the indicator is steady green for no more than 30 seconds, the CPU is being started. If the indicator is steady green for more than 30 seconds, the software is not running. |
Green | Slow blinking | The card software is running properly. | ||
Green | Fast blinking | The card software is starting. | ||
Red | Steady on | The switch has a 1600 W DC power module or 2400 W DC power module installed or experiences a card failure. Manual intervention is required. | ||
Yellow | Steady on | The card is powered off. (For example, the card is starting.) |
Silkscreen | Name | Description |
---|---|---|
RST | Reset button | Press this button to reset the card. |
Ports
1. One USB port |
2. One console port |
3. One ETH management port |
Port | Connector Type | Description | Available Components |
---|---|---|---|
USB port | USB 2.0 Type A | One USB port. A USB flash drive can be inserted into this port to load the system software to the switch during device deployment. | USB flash drive |
Console port | RJ45 | You can connect to a configuration terminal through this port for onsite configuration. | |
ETH management port | RJ45 | One ETH management port (10M/100M BASE-TX auto-sensing). It can connect to a network port of a configuration terminal or network management workstation to set up a local or remote configuration environment. |
Functions and Features
Functions and Features | Description |
---|---|
Basic functions | The MPU is the system control and management unit for the switch. It integrates the main control unit, clock unit, and system maintenance unit. |
OAM | The MPU supports the following OAM functions: 802.1ag: identifies, detects, and sends continuity check (CC) packets. Multiprotocol Label Switching (MPLS OAM): identifies, detects, and sends MPLS OAM packets. OAM UNCFG_MEP. |
Redundancy backup | 1+1 hot standby Main control board is mandatory for switches. Each switch must be configured with one or two main control boards. When one main control board is configured for a switch, the main control board can be installed in either main control board slot of the switch. When two main control boards are configured, the two main control boards work in hot standby mode to improve reliability of the switch. The active and standby main control boards monitor the status of each other. If the active main control board fails, the standby main control board automatically becomes active to ensure uninterrupted services. |
Hot swapping | Supported Before removing the active card, perform an active/standby switchover. |
Technical Specifications
Item | Specification |
---|---|
Dimensions without packaging (H x W x D) [mm(in.)] | 35.1 mm x 397.2 mm x 430.4 mm (1.38 in. x 15.64 in. x 16.94 in.) |
Dimensions with packaging (H x W x D) [mm(in.)] | 160 mm x 510 mm x 570 mm (6.30 in. x 20.08 in. x 22.44 in.) |
Weight without packaging [kg(lb)] | 2.60 kg (5.73 lb) |
Weight with packaging [kg(lb)] | 4.92 kg (10.85 lb) |
Typical power consumption [W] | 34 W |
Typical heat dissipation [BTU/hour] | 116.01 BTU/hour |
Maximum power consumption [W] | 40 W |
Maximum heat dissipation [BTU/hour] | 136.48 BTU/hour |
Memory | 8 GB, non-scalable |
Storage | NAND flash: 2 GB, built-in |