Advanced O&M Command Reference

OceanStor 2800 V3 V300R006

This document is applicable to OceanStor 2800 V3. Based on the CLI, this document describes how to use various commands classified by functionsand how to set the CLI and manage the storage system through these commands. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
change log_rate burst

change log_rate burst

Function

The change log_rate burst command is used to increase burst log quotas.

Format

change log_rate burst controller_id=? gid=? multiple=?

Parameters

Parameter

Description

Value

controller_id=?

Controller ID.

The value is in the format of "XA","XB","XC","XD", where the "X" is an integer ranging from 0 to 3.

gid=?

Process group ID.

The value must be an integer from 1 to 4,294,967,294 or "all", where:

  • an integer between 1 and 4,294,967,294: specific GID.
  • "all": all GIDs.

multiple=?

Multiple by which a burst log quota is to be increased.

The value must be an integer from 1 to 4,294,967,295.

Views

Developer view, Engineer view

Usage Guidelines

When "gid" is set to "all", burst log quotas of all GIDs increase by specific times.

Example

Increase the burst log quota of the process group whose GID is "2" by "10" times on controller "0A".

developer:/>change log_rate burst controller_id=0A gid=2 multiple=10 
Command executed successfully.

System Response

None

Translation