Advanced O&M Command Reference

OceanStor 2800 V3 V300R006

This document is applicable to OceanStor 2800 V3. Based on the CLI, this document describes how to use various commands classified by functionsand how to set the CLI and manage the storage system through these commands. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
reboot

reboot

Function

The reboot command is used to reset the SES through CPLD.

Format

reboot

Parameters

None

Modes

serial port mode

Usage Guidelines

  • When you run the command, the SES system will restart. It takes about 30 seconds for the SES system from a restart to stable running. If services are running during the interval, delivering I/Os into disks may be blocked and interrupted, thereby interrupting services.
  • Running this command is a highly risky operation. Execute this command with caution when there are ongoing services.

Example

Run the "reboot" command to reset the SES through CPLD.

PANGEA_SES:>reboot 
reboot cmd successful. 

************************************************************************ 
**                                                                    ** 
**                             SES System                             ** 
** COPYRIGHT(C) 2010-2020 HUAWEI,INC. ALL RIGHTS RESERVED.          ** 
**                                                                    ** 
************************************************************************ 

Boot version: R1-2016-02-20-B082 
enter the ThreadX kernel 

BoardType Gpio Value 0x31 
Get fwdl type:0x4, flag:0x0 
Get fwdl type:0x5, flag:0x0 
Get fwdl type:0x6, flag:0x0 
Get fwdl type:0x7, flag:0x0 
FruNum CRC Read 0x5a823a57, Saved 0x5a823a57, Magic 0xaced55aa 
Load Fan Register Funs! 
set ALL disk_phy ssc_type 0 under rate 0x8, enable 
Zone cfg iRv 0x0; Retry 1, valid is 1. 
Bbu auto online test switch:ff, iRv 0x20; Retry 10. 
Info: SASZONE init success, Zone enable state is 1. 
Buffering switch CRC Read 0x800bf16d, Saved 0xb621d97c, Magic 0xbcfbc3e9, Switch 988689274 
Local State Now Is Slave !INFO: FrameStatus From 0xff to 0x0 
Get fwdl type:0x3, flag:0xff 

Firmware internal  build: B082, Release 04.08.02 
Flash active image build: B001, Release 32.12.05, Release Type 04 
Flash active data(Init String)  build: B255, Release 55.55.15, Release Type 0f 
sas init ok 
Total Alarm len unexpect, dataLen: 539. 
It is not SAS card,no need to notify BMC 
Ses main start... 
BOARD:local eeprom self test result irv = 0x0 
Parse SysAlarmLed(0); SysPowerLed(0) by Uart 
Parse ucDevSetFrameSysAlarm=0 
Peer CustomRule_Mem, CRC 0x478d2258, FrameNumHex: 0

System Response

None

Translation
Download
Updated: 2019-07-12

Document ID: EDOC1000138381

Views: 719636

Downloads: 36

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next