This document is applicable to OceanStor 2800 V3. Based on the CLI, this document describes how to use various commands classified by functionsand how to set the CLI and manage the storage system through these commands. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
rsensor

rsensor

Function

The rsensor command is used to display information about a sensor.

Format

rsensor id

Parameters

Parameter

Description

Value

id

Sensor ID.

This value must be smaller than the number of sensors in the system; otherwise, a message indicating an invalid value will be displayed. To view the value range, you can run the rsensor command without parameters. A hexadecimal value is also supported.

Modes

serial port mode

Usage Guidelines

None

Example

Run the "rsensor 3" command to display information about sensor 3.

PANGEA_SES:> rsensor 3 
--------------------- Sensor INFO ------------------------------- 
owner_id(I2C Ad) : 90 
sensor_num : 3 
Sentity_id : 11 
sensor_type(1: temp 2:volt) : 1 
I2C_id : 0 
Switch_Ad : 112 
Switch_Chn : 4 
Alarm_threshold : 10 
AbnormalTimes : 0 
monitor_Value: 300 
alarm_status : 0 
nebs type : no nebs 
upper_critical_threshold : 700 
upper_critical_resume_threshold : 650 
upper_non_critical_threshold : 600 
upper_non_critical_resume_threshold: 550 
low_critical_threshold : 0 
low_critical_resume_threshold : 0 
low_non_critical_threshold : 0 
low_non_critical_resume_threshold : 0 
--------------------- End -----------------------------------------

System Response

The following table describes the parameter meanings.

Parameter

Meaning

owner_id(I2C Ad)

IIC address of a sensor.

sensor_num

Sensor ID.

Sentity_id

ID of a sensor in the sensor type.

sensor_type(1: temp 2:volt)

Sensor type ID.

I2C_id

IIC bus ID of a sensor.

Switch_Ad

IIC expander address.

Switch_Chn

IIC expander channel.

Alarm_threshold

Exception threshold for alarming. When the times of exceptions reach the threshold, an alarm will be generated.

AbnormalTimes

Alarm times for a sensor.

monitor_Value

Current monitoring value of a sensor.

alarm_status

Alarm status of a sensor.

nebs type

Whether it is the NEBS standard.

upper_critical_threshold

Higher threshold for level-2 alarms such as overvoltage alarms and level-2 overheating alarms. Not all sensors are configured with this threshold.

upper_critical_resume_threshold

Higher threshold for clearing level-2 alarms such as overvoltage alarms and level-2 overheating alarms. Not all sensors are configured with this threshold.

upper_non_critical_threshold

Higher threshold for level-1 alarms such as level-1 overheating alarms. Not all sensors are configured with this threshold.

upper_non_critical_resume_threshold

Higher threshold for clearing level-1 alarms such as level-1 overheating alarms. Not all sensors are configured with this threshold.

low_critical_threshold

Lower threshold for level-2 alarms such as undervoltage alarms and level-2 low temperature alarms. Not all sensors are configured with this threshold.

low_critical_resume_threshold

Lower threshold for clearing level-2 alarms such as undervoltage alarms and level-2 low temperature alarms. Not all sensors are configured with this threshold.

low_non_critical_threshold

Lower threshold for level-1 alarms such as level-1 low temperature alarms. Not all sensors are configured with this threshold.

low_non_critical_resume_threshold

Lower threshold for clearing level-1 alarms such as level-1 low temperature alarms. Not all sensors are configured with this threshold.

Translation