No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Advanced O&M Command Reference

OceanStor 2800 V3 V300R006

This document is applicable to OceanStor 2800 V3. Based on the CLI, this document describes how to use various commands classified by functionsand how to set the CLI and manage the storage system through these commands. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
epl showspec

epl showspec

Function

The epl showspec command is used to view the running information of EPL module.

Format

epl showspec

Parameters

None

Views

Diagnostic view

Usage Guidelines

None

Example

View the running information of EPL module.

admin:/diagnose>epl showspec 
maxPhyArray: 128. 
maxLogicArray: 64. 
maxPhyLink: 4096. 
maxObjPerNid: 512. 
localNid: 0. 
onlineNidMap: 3. 
sysWwn: 21000022a1072506. 
arraySn: 210235G6EJZ0B8242424. 
isStartOver: 1. 
EBC version of EPL : (404). 
System Upgrading Stat: (0). 
System Changing Master: (0). 

System Response

The following table describes the parameter meanings.

Parameter

Meaning

maxPhyArray

Size of external physical devices.

maxLogicArray

Size of external logical devices.

maxObjPerNid

Size of links on each controller.

maxPhyLink

Size of links on each controller.

localNid

Controller ID.

onlineNidMap

Bitmap of the online controllers.

sysWwn

Wwn of local system.

arraySn

Serial number of the device.

EBC version

Version of EBC message.

isStartWork

Sign of working status.

System Upgradeing status

Upgrading status of system.

System Changing Master

Master changing status.