Command Reference

OceanStor 2800 V3 V300R006

This document is applicable to OceanStor 2800 V3. Based on the CLI provided by the DeviceManager, this document describes how to use variouscommands classified by functions and how to set the CLI and manage the storage system throughthese commands. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
show storage_pool analysis_configuration

show storage_pool analysis_configuration

Function

The show storage_pool analysis_configuration command is used to check the predictive analysis configuration of a storage pool.

Format

show storage_pool analysis_configuration pool_id=?

Parameters

Parameter

Description

Value

pool_id=?

Storage pool ID.

To obtain the value, run the "show storage_pool general" command.

Level

Administrator

Usage Guidelines

The "show storage_pool analysis_configuration" command is executed to check the prediction analysis configuration of a storage pool.

Example

Check the predictive analysis configuration of storage pool "0".

admin:/>show storage_pool analysis_configuration pool_id=0 
Pool ID : 0 
Analysis Switch : Enable 
Analysis Switch Enable Time : 2014-09-26/14:34:22 UTC+08:00 
Tier0 Disk Type : SSD 
Tier1 Disk Type : SAS 
Tier2 Disk Type : NearLine SAS 
Tier0 RAID Level : RAID1 
Tier0 RAID Disk Number : 4 
Tier1 RAID Level : RAID5 
Tier1 RAID Disk Number : 5 
Tier2 RAID Level : RAID6 
Tier2 RAID Disk Number : 6 

System Response

The following table describes the parameter meanings.

Parameter

Meaning

Pool ID

Storage pool ID.

Analysis Switch

Whether to enable predictive analysis.

Analysis Switch Enable Time

Time when predictive analysis starts.

Tier0 Disk Type

Disk type of tier 0.

Tier1 Disk Type

Disk type of tier 1.

Tier2 Disk Type

Disk type of tier 2.

Tier0 RAID Level

RAID level of tier 0.

Tier0 RAID Disk Number

Number of member disks in a RAID group of tier 0.

Tier1 RAID Level

RAID level of tier 1.

Tier1 RAID Disk Number

Number of member disks in a RAID group of tier 1.

Tier2 RAID Level

RAID level of tier 2.

Tier2 RAID Disk Number

Number of member disks in a RAID group of tier 2.

Translation
Download
Updated: 2019-07-12

Document ID: EDOC1000138382

Views: 317991

Downloads: 38

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next