No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Advanced O&M Command Reference

OceanStor 18000 V3 Series V300R006

This document is applicable to OceanStor 18500 V3 and 18800 V3. Based on the CLI, this document describes how to use various commands classified by functionsand how to set the CLI and manage the storage system through these commands. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
change odx job_information

change odx job_information

Function

The change odx job_information command is used to configure the parameters for executing the odx command.

Format

change odx job_infomation { concurrent_value=? | speed=? } *

Parameters

Parameter

Description

Value

concurrent_value=?

Maximum concurrency for executing the command.

The value ranges from 1 to 128. The default value is 32.

speed=?

Speed at which the command is executed.

The value can be "low", "middle", "high", or "highest".

Views

Developer view

Usage Guidelines

This command is used to configure the speed limit of odx. If you want to cancel the limit on the odx command, run the "change odx job_information concurrent_value=32 speed=highest" command to set the parameter values to default values.

Example

Set the concurrent value to 32 and speed to highest, run the following command.

developer:/>change odx job_information concurrent_value=32 speed=highest 
WARNING: You are about to configure the parameters for executing the odx command. This operation will affect the performance of services related to the odx. If the speed is set too low, token handling may time out, and the odx copy is converted to a traditional copy. 
Have you read warning message carefully?(y/n)y 
Are you sure you really want to perform the operation?(y/n)y 
Command executed successfully.

System Response

None

Translation
Download
Updated: 2019-07-12

Document ID: EDOC1000138389

Views: 487858

Downloads: 85

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next