This document is applicable to OceanStor 18500 V3 and 18800 V3. Based on the CLI, this document describes how to use various commands classified by functions and how to set the CLI and manage the storage system through these commands. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
os showipconfig

os showipconfig

Function

The os showipconfig command is used to view the IP address configuration information of management ports on switches in the IP address configuration file.

Format

os showipconfig

Parameters

None

Views

Diagnostic view

Usage Guidelines

None

Example

View the IP address configuration information of management ports on switches in the IP address configuration file.

_user_admin:/diagnose>os showipconfig 

eth0IP_30=0.0.0.0 
eth0IP0=172.16.192.132 
eth1IP0=172.16.194.132 
eth0IP1=172.16.194.133 
eth1IP1=172.16.193.133 
MASK=255.255.255.0 
HOST1=172.16.192.0 
HOST0=172.16.193.0  
dsw0eth0vlantag=100 
dsw0eth1vlantag=100 
dsw1eth0vlantag=100 
dsw1eth1vlantag=100

System Response

The following table describes the parameter meanings.

Parameter

Meaning

eth0IP_30

IP address of port eth0 of the switch in the INI configuration file.

eth0IP0

IP address of port eth0 of the switch on plane 0 in the CONF file.

eth1IP0

IP address of port eth1 of the switch on plane 0 in the CONF file.

eth0IP1

IP address of port eth0 of the switch on plane 1 in the CONF file.

eth1IP1

IP address of port eth1 of the switch on plane 1 in the CONF file.

MASK

Mask in the CONF file.

HOST1

Target IP address of the route of the switch on plane 0 in the CONF file.

HOST0

Target IP address of the route of the switch on plane 1 in the CONF file.

dsw0eth0vlantag

Vlantag of port eth0 of the switch on plane 0 in the CONF file.

dsw0eth1vlantag

Vlantag of port eth1 of the switch on plane 0 in the CONF file.

dsw1eth0vlantag

Vlantag of port eth0 of the switch on plane 1 in the CONF file.

dsw1eth1vlantag

Vlantag of port eth1 of the switch on plane 1 in the CONF file.