This document is applicable to OceanStor 18500 V3 and 18800 V3. Based on the CLI, this document describes how to use various commands classified by functions and how to set the CLI and manage the storage system through these commands. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
change dedup_lun rescue

change dedup_lun rescue

Function

The change dedup_lun rescue command is used to execute the dedup LUN rescue repair.

Format

change dedup_lun rescue controller=? lun_id=? action=? [ force=? ] [ data_check=? ] [ speed=? ]

Parameters

Parameter

Description

Value

controller=?

Indicates the owning controller of the LUN.

The value is in the format of XA or XB or XC or XD.X can be 0 to 3.

lun_id=?

LUN ID.

The value ranges from 0 to 65535.

action=?

Action.

The value is "start", "cancel", "confirm", "clear" where:

  • "start": start.
  • "cancel": cancel.
  • "confirm": confirm.
  • "clear": clear.

force=?

Forcible check tag.

The value is "no" or "yes", where:

  • "no": indicates that forcible repair will not be performed.
  • "yes": indicates that forcible repair will be performed.

data_check=?

Data check tag.

The value is "no" or "yes", where:

  • "no": indicates that data check will not be performed.
  • "yes": indicates that data check will be performed.

speed=?

Scanning speed.

Possible values are "high", "normal", where:

  • "high": the highest scanning speed, which will have a significant impact on system performance.
  • "normal": normal scanning speed, which will have a fair impact on system performance.

Views

Developer view

Usage Guidelines

None

Example

  • To rescue the LUN whose ID is "0", run the following command.
    developer:/>change dedup_lun rescue controller=0A lun_id=0 action=start 
    DANGER: You are about to rescue the LUN. When performing this operation, note the following: 
    1. Before the rescuing, ensure that the storage pool to which the LUN belongs is normal and 10 percent free space is reserved.  
    2. During the rescuing, do not perform any operations on the storage system or the LUN.  
    3. Rescuing a LUN may lose some data on the LUN and rescue some old data or deleted data.  
    4. After successful rescuing, the available space of the LUN may be greater than, smaller than, or equal to the available capacity before the rescuing.  
    5. If data is added or modified upon successful rescuing, the deduplication and compression ratio may decrease.  
    6. After successful rescuing, run the confirm command to confirm the rescuing. If the rescuing fails or is interrupted, run the cancel command to cancel the rescuing.  
    Suggestion: Perform this operation based on customer requirements. 
    Have you read danger alert message carefully?(y/n)y 
    Are you sure you really want to perform the operation?(y/n)y 
    Command executed successfully.
  • To cancel the LUN rescue task whose ID is "0", run the following command.
    developer:/>change dedup_lun rescue controller=0A lun_id=0 action=cancel 
    DANGER: You are about to cancel the rescuing task. When performing this operation, note the following: 
    1. When canceling the rescuing task, do not perform other operations on the storage system or the LUN. 
    2. Only failed rescuing task can be canceled.  
    3. The canceling operation cannot reclaim the space obtained by a rescuing task that failed in the online phase during restoration. 
    4. After this command is executed successfully, run the show command to view the status and progress of the task canceling.  
    5. After a rescuing task is successfully canceled, you cannot view the status of the task by running the show command. 
    Suggestion: Perform this operation based on customer requirements. 
    Have you read danger alert message carefully?(y/n)y 
    Are you sure you really want to perform the operation?(y/n)y 
    Command executed successfully.
  • To confirm the LUN rescue task whose ID is "0", run the following command.
    developer:/>change dedup_lun rescue controller=0A lun_id=0 action=confirm 
    DANGER: You are about to confirm the rescuing task. When performing this operation, note the following: 
    1. When confirming the rescuing task, do not perform other operations on the storage system or the LUN. 
    2. You can only confirm successful rescuing task.  
    3. After the command is executed successfully, you cannot view the status of the rescuing task by running the show command. 
    Suggestion: Perform this operation based on customer requirements. 
    Have you read danger alert message carefully?(y/n)y 
    Are you sure you really want to perform the operation?(y/n)y 
    Command executed successfully.
  • To clear the LUN rescue task whose ID is "0", run the following command.
    developer:/>change dedup_lun rescue controller=0A lun_id=0 action=clear 
    DANGER: You are about to clear the rescuing task. When performing this operation, note the following: 
    1. When clearing the rescuing task, do not perform other operations on the storage system or the LUN. 
    2. Clearing a failed rescuing task cannot reclaim the space obtained during the rescuing.  
    3. After the command is executed successfully, you cannot view the status of the task by running the show command. 
    Suggestion: Perform this operation based on customer requirements. 
    Have you read danger alert message carefully?(y/n)y 
    Are you sure you really want to perform the operation?(y/n)y 
    Command executed successfully.

System Response