This document is applicable to OceanStor 18500 V3 and 18800 V3. Based on the CLI, this document describes how to use various commands classified by functionsand how to set the CLI and manage the storage system through these commands. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
change dif_scan enabled

change dif_scan enabled

Function

The change dif_scan enabled command is used to start or stop the LUN DIF scan.

Format

change dif_scan enabled enabled=? [ lun_id=? ] [ lba=? length=? ]

Parameters

Parameter

Description

Value

enabled=?

Starts or stops the LUN DIF scan.

The value can be "start" or "stop".

lun_id=?

LUN ID.

To obtain the value, run the "show lun general" command without parameters.

lba=?

Start LBA of the LUN DIF scan.

The maximum value cannot exceed the maximum capacity of the LUN. The value ranges from 0 to 549755813887.

length=?

Length of the LUN DIF scan.

The maximum value cannot exceed the maximum capacity of the LUN. The value ranges from 1 to 549755813888.

Views

Developer view

Usage Guidelines

This command is applicable only to the local controller.

Example

  • Start the LUN DIF scan.
    developer:/>change dif_scan enabled enabled=start lun_id=0 lba=0 length=100 
    Command executed successfully.
  • Stop the LUN DIF scan on the controller.
    developer:/>change dif_scan enabled enabled=stop 
    Command executed successfully.

System Response