This document is applicable to OceanStor 18500 V3 and 18800 V3. Based on the CLI provided by the DeviceManager, this document describes how to use variouscommands classified by functions and how to set the CLI and manage the storage system throughthese commands. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
change enclosure light

change enclosure light

Function

The change enclosure light command is used to set the status of the location indicator on a specific engine or disk enclosure. You can run this command to query the location of an engine or disk enclosure.

Format

change enclosure light enclosure_number=? on_or_off=?

Parameters

Parameter

Description

Value

enclosure_number=?

ID of an engine or disk enclosure.

To obtain the value, run "show enclosure".

on_or_off=?

Status of a location indicator.

The value can be "on" or "off", where:

  • "on": The location indicator will be turned on.
  • "off": The location indicator will be turned off.

Level

Administrator

Usage Guidelines

None

Example

To turn on the location indicator on the disk enclosure whose ID is "DAE000", run the following command. The command output varies depending on a specific product.

admin:/>change enclosure light enclosure_number=DAE000 on_or_off=on 
Command executed successfully.

System Response

None

Translation