This document is applicable to OceanStor 18500 V3 and 18800 V3. Based on the CLI provided by the DeviceManager, this document describes how to use variouscommands classified by functions and how to set the CLI and manage the storage system throughthese commands. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
show fan

show fan

Function

The show fan command is used to query details on fan modules. Run this command if you need to query a fan module's status, running speed, running level and electronic label.

Format

show fan [ fan_id=? ]

Parameters

Parameter

Description

Value

fan_id=?

ID of a fan module.

To obtain the value, run "show fan" without parameters.

Level

Guest

Usage Guidelines

  • To query details on all fan modules, run show fan.
  • To query details on a specific fan module, run show fan fan_id=?.

Example

Query details on all fan modules. The command output varies depending on a specific product.

admin:/>show fan 

ID Name Health Status Running Status Running Level 
------------ ----- ------------- -------------- ------------- 
ENG0.0 0 Normal Running Low 
ENG0.1 1 Normal Running Low 
ENG0.2 2 Normal Running Low 
DAE000.FAN.0 FAN 0 Normal Running Low 
DAE000.FAN.1 FAN 1 Normal Running Low 
DAE000.FAN.2 FAN 2 Normal Running Low 
DAE000.FAN.3 FAN 3 Normal Running Low

System Response

The following table describes the parameter meanings.

Parameter

Meaning

ID

Fan module ID.

Name

Fan module name.

Health Status

Health status of the fan module.

Running Status

Running status of the fan module.

Running Level

Running level of the fan module.

Electronic Label

Electronic label of the fan module.