Command Reference

OceanStor 18000 V3 Series V300R006

This document is applicable to OceanStor 18500 V3 and 18800 V3. Based on the CLI provided by the DeviceManager, this document describes how to use variouscommands classified by functions and how to set the CLI and manage the storage system throughthese commands. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
show lun hyper_metro_pair

show lun hyper_metro_pair

Function

The show lun hyper_metro_pair command is used to query information about LUNs for which HyperMetro is configured.

Format

show lun hyper_metro_pair lun_mapped=?

Parameters

Parameter

Description

Value

lun_mapped=?

Whether HyperMetro LUNs are mapped.

The value can be "yes" or "no", where:

  • "yes": The HyperMetro LUN has been mapped.
  • "no": The HyperMetro LUN has not been mapped.

Level

Guest

Usage Guidelines

This command can only be used to query information about HyperMetro LUNs on the local storage system.

Example

Query HyperMetro LUNs that are not mapped.

admin:/>show lun hyper_metro_pair lun_mapped=no  
ID  Name        Pool ID  Capacity  Health Status  Running Status  Type  WWN                               Is Add To Lun Group  Smart Cache Partition ID  DIF Switch 
  --  ----------  -------  --------  -------------  --------------  ----  --------------------------------  -------------------  ------------------------  ---------- 
  0 LUN0010000  0        5.000GB Normal         Online          Thin  60c45ba100a1f330000a451200000000  Yes                  --                        No           
  1 LUN0010001  0        5.000GB Normal         Online          Thin  60c45ba100a1f330000a45b100000001  Yes                  --                        No           
  2 LUN0010002  0        5.000GB Normal         Online          Thin  60c45ba100a1f330000a468a00000002  Yes                  --                        No           
  3 LUN0010003  0        5.000GB Normal         Online          Thin  60c45ba100a1f330000a474100000003  Yes                  --                        No           
  4 LUN0010004  0        5.000GB Normal         Online          Thin  60c45ba100a1f330000a481c00000004  Yes                  --                        No           
  5 LUN0010005  0        5.000GB Normal         Online          Thin  60c45ba100a1f330000a48b400000005  Yes                  --                        No           
  6 LUN0010006  0        5.000GB Normal         Online          Thin  60c45ba100a1f330000a497500000006  Yes                  --                        No

System Response

The following table describes the parameter meanings.

Parameter

Meaning

ID

LUN ID.

Name

LUN name.

Pool ID

Storage pool ID.

Capacity

Total capacity.

Health Status

Health status.

Running Status

Running status.

Type

LUN type.

WWN

World Wide Name.

Is Add To Lun Group

Whether a LUN has been added to a LUN group.

Smart Cache Partition ID

SmartCache partition ID.

DIF Switch

Whether to enable the DIF function.

Translation