No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Command Reference

OceanStor 18000 V3 Series V300R006

This document is applicable to OceanStor 18500 V3 and 18800 V3. Based on the CLI provided by the DeviceManager, this document describes how to use variouscommands classified by functions and how to set the CLI and manage the storage system throughthese commands. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
show failover_group member

show failover_group member

Function

The show failover_group member command is used to query the members in a failover group on the storage system.

Format

show failover_group member failover_group_id=? [ type=? ]

Parameters

Parameter

Description

Value

failover_group_id=?

Indicates the ID of the failover group.

The value is an integer between 0 and 8191.

type=?

Indicates the type of the object in the failover group.

The value can be "eth_port", "bond_port", or "vlan", where:

  • "eth_port": Ethernet port.
  • "bond_port": bond port.
  • "vlan": VLAN port.

Level

Guest

Usage Guidelines

  • You can run the "show failover_group member failover_group_id=?" command to query the Ethernet ports, bond port, and VLAN port in a specified failover group. Fibre Channel ports in a failover group cannot be queried.
  • You can run the "show failover_group member failover_group_id=0 type=?" command to query information about a failover group with a specified port type.

Example

  • Query the Ethernet network ports, bond ports, and VLAN ports in failover group "0".
    admin:/>show failover_group member failover_group_id=0 
    ETH Port: 
      ID              Health Status  Running Status  Type       IPv4 Address  IPv6 Address  MAC                Role         Working Rate(Mbps) 
      --------------  -------------  --------------  ---------  ------------  ------------  -----------------  -----------  ------------------ 
      CTE0.A.H0       Normal         Link Up         Host Port  --            --            d4:94:e8:0d:5d:62  INI and TGT  1000                 
      CTE0.A.H1       Normal         Link Up         Host Port  --            --            d4:94:e8:0d:5d:64  INI and TGT  1000                 
      CTE0.A.H2       Normal         Link Down       Host Port  --            --            d4:94:e8:0d:5d:61  INI and TGT  --                   
      CTE0.A.H3       Normal         Link Down       Host Port  --            --            d4:94:e8:0d:5d:63  INI and TGT  --                   
      CTE0.A.IOM0.P0  Normal         Link Down       Host Port  --            --            04:9f:ca:05:33:ea  INI and TGT  --                   
      CTE0.A.IOM0.P1  Normal         Link Down       Host Port  --            --            04:9f:ca:05:33:eb  INI and TGT  --                   
      CTE0.A.IOM0.P2  Normal         Link Down       Host Port  --            --            04:9f:ca:05:33:ec  INI and TGT  --                   
      CTE0.A.IOM0.P3  Normal         Link Down       Host Port  --            --            04:9f:ca:05:33:ed  INI and TGT  --                   
      CTE0.B.H2       Normal         Link Down       Host Port  --            --            d4:94:e8:0d:5d:3e  INI and TGT  --                   
      CTE0.B.H3       Normal         Link Down       Host Port  --            --            d4:94:e8:0d:5d:40  INI and TGT  --                   
      CTE0.B.IOM0.P0  Normal         Link Down       Host Port  --            --            7c:a2:3e:e1:f4:52  INI and TGT  --                   
      CTE0.B.IOM0.P1  Normal         Link Down       Host Port  --            --            7c:a2:3e:e1:f4:53  INI and TGT  --                   
      CTE0.B.IOM0.P2  Normal         Link Down       Host Port  --            --            7c:a2:3e:e1:f4:54  INI and TGT  --                   
      CTE0.B.IOM0.P3  Normal         Link Down       Host Port  --            --            7c:a2:3e:e1:f4:55  INI and TGT  --                   
    Bond Port: 
      ID            Name      Health Status  Running Status  MTU Port ID List          
      ------------  --------  -------------  --------------  ----  ------------------- 
      549772730113  bond_1_1  Normal         Link Up         1500  CTE0.B.H0,CTE0.B.H1 
    VLAN: 
      Name         Running Status  VLAN ID  MTU Port Type  Port ID     
      -----------  --------------  -------  ----  ---------  --------- 
      bond_1_1.1 Link Up         1        1500  Bond       bond_1_1  
  • Query the Ethernet network ports in failover group "0".
    admin:/>show failover_group member failover_group_id=0 type=eth_port 
      ID              Health Status  Running Status  Type       IPv4 Address  IPv6 Address  MAC                Role         Working Rate(Mbps) 
      --------------  -------------  --------------  ---------  ------------  ------------  -----------------  -----------  ------------------ 
      CTE0.A.H0       Normal         Link Up         Host Port  --          --            d4:94:e8:0d:5d:62  INI and TGT  1000                 
      CTE0.A.H1       Normal         Link Up         Host Port  --            --            d4:94:e8:0d:5d:64  INI and TGT  1000                 
      CTE0.A.H2       Normal         Link Down       Host Port  --            --            d4:94:e8:0d:5d:61  INI and TGT  --                   
      CTE0.A.H3       Normal         Link Down       Host Port  --            --            d4:94:e8:0d:5d:63  INI and TGT  --                   
      CTE0.A.IOM0.P0  Normal         Link Down       Host Port  --            --            04:9f:ca:05:33:ea  INI and TGT  --                   
      CTE0.A.IOM0.P1  Normal         Link Down       Host Port  --            --            04:9f:ca:05:33:eb  INI and TGT  --                   
      CTE0.A.IOM0.P2  Normal         Link Down       Host Port  --            --            04:9f:ca:05:33:ec  INI and TGT  --                   
      CTE0.A.IOM0.P3  Normal         Link Down       Host Port  --            --            04:9f:ca:05:33:ed  INI and TGT  --                   
      CTE0.B.H2       Normal         Link Down       Host Port  --            --            d4:94:e8:0d:5d:3e  INI and TGT  --                   
      CTE0.B.H3       Normal         Link Down       Host Port  --            --            d4:94:e8:0d:5d:40  INI and TGT  --                   
      CTE0.B.IOM0.P0  Normal         Link Down       Host Port  --            --            7c:a2:3e:e1:f4:52  INI and TGT  --                   
      CTE0.B.IOM0.P1  Normal         Link Down       Host Port  --            --            7c:a2:3e:e1:f4:53  INI and TGT  --                   
      CTE0.B.IOM0.P2  Normal         Link Down       Host Port  --            --            7c:a2:3e:e1:f4:54  INI and TGT  --                   
      CTE0.B.IOM0.P3  Normal         Link Down       Host Port  --            --            7c:a2:3e:e1:f4:55  INI and TGT  -- 
  • Query the bond port in failover group "0".
    admin:/>show failover_group member failover_group_id=1 type=bond_port 
      ID            Name      Health Status  Running Status  MTU Port ID List          
      ------------  --------  -------------  --------------  ----  ------------------- 
      549772730113  bond_1_1  Normal         Link Up         1500  CTE0.B.H0,CTE0.B.H1 
  • Query VLAN port in failover group "4184".
    admin:/>show failover_group member failover_group_id=4184 type=vlan 
      
      Name         Running Status  VLAN ID  MTU Port Type  Port ID     
      -----------  --------------  -------  ----  ---------  --------- 
      bond_1_1.1 Link Up         1        1500  Bond       bond_1_1  

System Response

The following table describes the parameter meanings.

Parameter

Meaning

ETH Port

Indicates the Ethernet port in a failover group.

Bond Port

Indicates the bond port in a failover group.

VLAN

Indicates the VLAN port in a failover group.

Translation
Download
Updated: 2019-07-12

Document ID: EDOC1000138390

Views: 228332

Downloads: 150

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next