This document is applicable to OceanStor 18500 V3 and 18800 V3. Based on the CLI provided by the DeviceManager, this document describes how to use variouscommands classified by functions and how to set the CLI and manage the storage system throughthese commands. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
change smtp_server config

change smtp_server config

Function

The change smtp_server config command is used to configure the email-based alarm notification function. If you want to enable the storage system to automatically send an alarm notification email to a specified mailbox when an alarm is generated, run this command.

Format

change smtp_server config { enabled=? | sender=? | authentication=? [ user=? password=? ] | connection_security=? | smtp_server_port=? | { clear_email_title_prefix=? | email_title_prefix=? } | email_title_level_enable=? } *

Parameters

Parameter

Description

Value

enabled=?

Whether to enable the email-based notification function.

The value can be "yes" or "no", where:

  • "yes": To enable the email-based alarm notification function.
  • "no": Not to enable the email-based alarm notification function.

The default value is "no".

sender=?

Sender email.

The value contains 5 to 255 characters.

authentication=?

Whether the SMTP server must be verified by a user.

The value can be "yes" or "no", where:

  • "yes": Verification is required.
  • "no": Verification is not required.

user=?

Username used to log in to the SMTP server.

NOTE:

This parameter can be specified when "authentication" is set to "yes".

The value consists of 1 to 63 ASCII characters except single quotation marks ('), double quotation marks (") and question marks (?).

password=?

Password used to log in to the SMTP server.

NOTE:

This parameter can be specified when "authentication" is set to "yes".

The value consists of 1 to 63 ASCII characters except question mark (?).

connection_security=?

Secure connection mode between the email sending server and the client.

The value can be "none", "ssl/tls", or "starttls", where:

  • "none": No secure connection mode is used.
  • "ssl/tls": ssl/tls is used to encrypt connections to ensure connection security.
  • "starttls": starttls is used.
NOTE:

To ensure data transfer security, secure connection modes are recommended.

smtp_server_port=?

Port number of the SMTP server.

The value is an integer from 1 to 65535.

email_title_prefix=?

Email title prefix.

The value consists of 1 to 511 ASCII characters, it cannot contain single quotes (').

clear_email_title_prefix=?

Clears the email prefix.

If the value is "yes", the email title prefix is cleared.

email_title_level_enable=?

Whether to show alarm severities in email titles.

The value can be "yes" or "no", where:

  • "yes": show alarm severities in email titles.
  • "no": Not to show alarm severities in email titles.

Level

Administrator

Usage Guidelines

  • Before running this command, configure an SMTP server and a valid SMTP account.
  • You must configure a sender during the initial configuration.
  • You must configure the username and password when you set authentication to yes for the first time.
  • After alarm notification by email is configured, the system sends alarms to specified mailboxes by email. The email format is as follows:

    Dear OceanStor XXXXX users:

    System Name: Huawei.Storage

    Location: China

    Customer Info: ClientName

    ESN: XXXXXXXXXXXXXXXXXXXX

    ID: 0x1FFFFFFFFFFFFFFB

    Level: Informational

    Occurred At: 2015-06-23 15:58:53

    Details: This is a test message.

    Suggestions: N/A

  • Each part of the email content is defined as follows:
    • Manufacturer and product type, for example, OceanStor XXXXX.
    • Device name, for example, Huawei.Storage.
    • Client of the storage system, for example, ClientName.
    • Device SN, for example, XXXXXXXXXXXXXXXXXXXX.
    • Alarm ID, which indicates a certain type of alarm, expressed in the hexadecimal format, for example, 0x1FFFFFFFFFFFFFFB.
    • Alarm severity. Alarm severities include info, warning, major, and critical.
    • Time when an alarm occurs, for example, 2015-06-23 15:03:36.
    • Alarm description, for example, "This Is A Test Message.".
    • Alarm clearance suggestion, for example, N/A.
  • The value of "connection_security" must be consistent with that in the mailbox server configuration. Otherwise, emails cannot be successfully sent.
  • The query command that corresponds to this command is "show notification email_extend".
  • The following parameters or parameter sets are mutually exclusive: clear_email_title_prefix and email_title_prefix.

Example

Enable the email-based notification function and set the sender email address to "XXXXXX@foxmail.com", SMTP server port to "4232", security connection mode to "ssl/tls", username and password for authenticating the email sending server to "admin" and "123456", email title prefix to "new", and the switch of displaying alarm severities in email titles to "yes".

admin:/>change smtp_server config enabled=yes sender=XXXXXX@foxmail.com authentication=yes user=admin password=****** connection_security=ssl/tls smtp_server_port=4232 email_title_prefix=new email_title_level_enable=yes 
Change configuration successfully.

System Response

None