No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Advanced O&M Command Reference

OceanStor 2000, 5000, and 6000 V3 Series V300R006

This document is applicable to OceanStor 2200 V3, 2600 V3 Video Surveillance Edition, 2600 V3, 5300 V3, 5500 V3, 5600 V3, 5800 V3, and 6800 V3. Based on the CLI, this document describes how to use various commands classified by functionsand how to set the CLI and manage the storage system through these commands. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
bdm_efuseswitch.sh

bdm_efuseswitch.sh

Function

The bdm_efuseswitch.sh command is used to show or modify the efuse check function when disks are present.

Format

bdm_diskbomlist.sh { -h | -a | -q | 0 | 1}

Parameters

Parameter

Description

Value

-h

Shows help information.

-

-a

Shows functions of each subcommand of the BDM module.

-

-q

Shows whether the efuse check function is enabled when disks are present.

-

0

Disables the efuse check function when disks are present.

-

1

Enables the efuse check function when disks are present.

-

Modes

Minisystem mode

Usage Guidelines

  • The bdm_efuseswitch.sh 0 command is used to disable the efuse check function when disks are present.
  • The bdm_efuseswitch.sh 1 command is used to enable the efuse check function when disks are present.
  • The bdm_efuseswitch.sh -q command is used to show whether the efuse check function is enabled when disks are present.
  • The bdm_efuseswitch.sh -h command is used to show help information.
  • The bdm_efuseswitch.sh -a command is used to show functions of each subcommand.

Example

  • Disable the efuse check function when disks are present.
    Storage: minisystem> bdm_efuseswitch.sh 0 
    admin:/diagnose>sddebug efusecheckswitch 0 
    [BDM SD]Success to set efuse check switch 0. 
    admin:/diagnose>exit 
  • Enable the efuse check function when disks are present.
    Storage: minisystem> bdm_efuseswitch.sh 1 
    admin:/diagnose>sddebug efusecheckswitch 1 
    [BDM SD]Success to set efuse check switch 1. 
    admin:/diagnose>exit
  • Show whether the efuse check function is enabled when disks are present.
    Storage: minisystem> bdm_efuseswitch.sh -q 
    admin:/diagnose>sddebug getefusecheckswitch 
    [BDM SD]Success to get current efuse check switch 1. 
    admin:/diagnose>exit 

System Response

None

Translation