No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Advanced O&M Command Reference

OceanStor 2000, 5000, and 6000 V3 Series V300R006

This document is applicable to OceanStor 2200 V3, 2600 V3 Video Surveillance Edition, 2600 V3, 5300 V3, 5500 V3, 5600 V3, 5800 V3, and 6800 V3. Based on the CLI, this document describes how to use various commands classified by functions and how to set the CLI and manage the storage system through these commands. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
delete configuration_log

delete configuration_log

Function

The delete configuration_log command is used to delete specific configuration log in the system.

Format

delete configuration_log log_id=?

Parameters

Parameter

Description

Value

log_id=?

Log ID.

To obtain the value, run the "show system configuration_log" command.

Views

Developer view

Usage Guidelines

To delete a specific configuration log in the system, run the "delete configuration_log log_id=?" command. After this operation, the configuration operation recorded in this log cannot be redone.

Example

Delete a specific configuration log in the system.

developer:/>delete configuration_log log_id=0 
DANGER: You are about to delete the configuration log. After this operation, the abnormal configuration operation recorded in this log cannot be redone. 
Suggestion: Before performing this operation, contact technical support engineers and note the following: 
1. Ensure that this command is only used for the upgrade. 
2. Perform this configuration operation again after the upgrade. 
Have you read danger alert message carefully?(y/n)y 

Are you sure you really want to perform the operation?(y/n)y 
Command executed successfully.

System Response

None

Translation
Download
Updated: 2019-07-12

Document ID: EDOC1000138402

Views: 640738

Downloads: 707

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next