This document is applicable to OceanStor 2200 V3, 2600 V3 Video Surveillance Edition, 2600 V3, 5300 V3, 5500 V3, 5600 V3, 5800 V3, and 6800 V3. Based on the CLI, this document describes how to use various commands classified by functionsand how to set the CLI and manage the storage system through these commands. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
xnet showctrlmsgnum

xnet showctrlmsgnum

Function

The xnet showctrlmsgnum command is used to query the PIDs and number of modules that have control messages.

Format

xnet showctrlmsgnum

Parameters

None

Views

Diagnostic view

Usage Guidelines

  • This command is used by development engineers to locate faults.
  • When messages are blocked or fail to be sent, run the command.

Example

Query the PIDs and number of modules that have control messages.

admin:/diagnose>xnet showctrlmsgnum 
Pid (2) ctrl msg num is (9) 
Pid (228) ctrl msg num is (159) 
Current user super msg num is (0), upper limit is (60).

System Response

The following table describes the parameter meanings.

Parameter

Meaning

Super msg num

Number of super messages of the current user.

upper limit

Upper limit of the super message number.

Pid

PID of the service module.

ctrl msg num

Number of control messages.