Advanced O&M Command Reference

OceanStor 2000, 5000, and 6000 V3 Series V300R006

This document is applicable to OceanStor 2200 V3, 2600 V3 Video Surveillance Edition, 2600 V3, 5300 V3, 5500 V3, 5600 V3, 5800 V3, and 6800 V3. Based on the CLI, this document describes how to use various commands classified by functionsand how to set the CLI and manage the storage system through these commands. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
sys showfrustatus

sys showfrustatus

Function

The sys showfrustatus command is used to view the status of field replaceable units (FRUs).

Format

sys showfrustatus

Parameters

None

Views

Diagnostic view

Usage Guidelines

None

Example

View the status of FRUs.

admin:/diagnose>sys showfrustatus 
Fru state is 0x0 . 
cacheState            : back 
engineVaultState      : normal 
hightempState         : recover one 
singleNodeWriteThrough: close 
 node id type             status  
 ------- -------------- ------  
 0         BBU              normal  
 0         SSD              normal  
 0         boardTempState recover one  
 1         BBU              normal  
 1         SSD              normal  
 1         boardTempState recover one  
admin:/diagnose>

System Response

The following table describes the parameter meanings.

Parameter

Meaning

Fru state is

Current FRU status.

cacheState

Write-back/write-through status of cache.

engineVaultState

Coffer disk status.

hightempState

High temperature status.

singleNodeWriteThrough

Switch of single-node write through.

node id

Node ID.

type

FRU type.

status

Status.

Translation