This document is applicable to OceanStor 2200 V3, 2600 V3 Video Surveillance Edition, 2600 V3, 5300 V3, 5500 V3, 5600 V3, 5800 V3, and 6800 V3. Based on the CLI, this document describes how to use various commands classified by functionsand how to set the CLI and manage the storage system through these commands. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ssdc show copyspeed

ssdc show copyspeed

Function

The ssdc show copyspeed command is used to query the copy speed of the current controller.

Format

ssdc show copyspeed

Parameters

None

Views

Diagnostic view

Usage Guidelines

OceanStor 2100 V3/6800 V3/2200 V3/2600 V3/5300 V3/5500 V3/5600 V3/5800 V3 storage systems support this command.

Example

Query the copy speed of the current controller.

 admin:/diagnose>ssdc show copyspeed 
|CopySpeed(spec)(MB) |maxCapInterval(sec) |sendCap(sec) |historyCap(sec) |copyIoNum |stopCount | 
|100 |16384 |2144 |24408684 |2 |0 |

System Response

The following table describes the parameter meanings.

Parameter

Meaning

CopySpeed(spec)(MB)

Copy speed (specifications).

maxCapInterval(sec)

Maximum capacity of data that can be copied in each interval.

sendCap(sec)

Total capacity that has been sent recently.

historyCap(sec)

Total history capacity that has been sent.

copyIoNum

Number of copy I/Os that have been sent.

stopCount

Number of commands used to stop copy.