Advanced O&M Command Reference

OceanStor 2000, 5000, and 6000 V3 Series V300R006

This document is applicable to OceanStor 2200 V3, 2600 V3 Video Surveillance Edition, 2600 V3, 5300 V3, 5500 V3, 5600 V3, 5800 V3, and 6800 V3. Based on the CLI, this document describes how to use various commands classified by functionsand how to set the CLI and manage the storage system through these commands. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
change hyper_metro most_domain_enabled

change hyper_metro most_domain_enabled

Function

The change hyper_metro most_domain_enabled command is used to enable the large-specification HyperMetro domain function that allows the number of supported HyperMetro domains to exceed the upper limit.

Format

change hyper_metro most_domain_enabled enabled=?

Parameters

Parameter

Description

Value

enabled

Whether the large-specifications HyperMetro domain function is enabled.

The value can be "yes", where:

"yes": The function is enabled.

Views

Developer view

Usage Guidelines

To enable the large-specification HyperMetro domain function, run the "change hypermetro most_domain_enabled enabled=yes" command in developer mode on two storage arrays separately.

OceanStor 6800 V3/2600 V3/5300 V3/5500 V3/5600 V3/5800 V3 storage systems support this command.

Example

Enable the large-specifications HyperMetro domain function.

developer:/>change hyper_metro most_domain_enable enabled=yes 
Command executed successfully.

System Response

None