Advanced O&M Command Reference

OceanStor 2000, 5000, and 6000 V3 Series V300R006

This document is applicable to OceanStor 2200 V3, 2600 V3 Video Surveillance Edition, 2600 V3, 5300 V3, 5500 V3, 5600 V3, 5800 V3, and 6800 V3. Based on the CLI, this document describes how to use various commands classified by functions and how to set the CLI and manage the storage system through these commands. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
change odx odx_enabled

change odx odx_enabled

Function

The change odx odx_enabled command is used to set the switch of ODX.

Format

change odx odx_enabled enabled=?

Parameters

Parameter

Description

Value

enabled=?

Switch of ODX.

The value can be "yes" or "no", where:

  • "yes": The ODX will be enabled.
  • "no": The ODX will be disabled.

Views

Developer view

Usage Guidelines

To enable or disable the ODX function on a storage system, perform the following steps.

  • Run the following command to enable or disable the ODX function.
    • Run the "change odx odx_enabled enabled=yes" command to enable the ODX function.
    • Run the "change odx odx_enabled enabled=no" command to disable the ODX function.
  • Restart the storage system (this operation stops all services running on the storage system).
  • After the device is powered on, uninstall physical disks and virtual disks generated by the multipathing software in the disk manager for mapped LUNs and rescan the disks (that is, operate the disks as new disks after clearing residual disk information).

Example

To set the switch of ODX, run the following command.

developer:/>change odx odx_enabled enabled=no 
WARNING: You are about to enable or disable the ODX function, this operation may cause some influence of the function. 
Suggestion: After performing this operation, complete the following operations: 
1. Restart the storage system (this operation stops all services running on the storage system). 
2. After the device is powered on, uninstall physical disks and virtual disks generated by the multipathing software in the disk manager for mapped LUNs and rescan the disks (that is, operate the disks as new disks after clearing residual disk information). 
Have you read warning message carefully?(y/n)y 
Are you sure you really want to perform the operation?(y/n)y 
Command executed successfully.