This document is applicable to OceanStor 2200 V3, 2600 V3 Video Surveillance Edition, 2600 V3, 5300 V3, 5500 V3, 5600 V3, 5800 V3, and 6800 V3. Based on the CLI, this document describes how to use various commands classified by functionsand how to set the CLI and manage the storage system through these commands. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
sysforcepoweron

sysforcepoweron

Function

The sysforcepoweron command is used to set the forcible power-on switch of the system control module.

Format

sysforcepoweron [ switch flag ]

Parameters

Parameter

Description

Value

switch flag

Forcible power-on switch flag.

The value is 0 or 1.

  • 0: open, indicates that the switch is on. Some check items are ignored when the system control module powers on the system and the system will be forcibly powered on.
  • 1: close, indicates that the switch is off.

Modes

Minisystem mode

Usage Guidelines

  • After this command is executed, the memory fault check during power-on will be skipped.
  • The power-on may fail due to inconsistent memory.
  • The forced power-on may result in service interruption.

Example

Set the forcible power-on switch of the system control module.

Storage: minisystem> sysforcepoweron 0 
admin:/diagnose>sys setforcepoweronswitch 0 
Set force power on switch flag : open. 
admin:/diagnose>exit 
Storage: minisystem> sysforcepoweron 1 
admin:/diagnose>sys setforcepoweronswitch 1 
Set force power on switch flag : close. 
admin:/diagnose>exit

System Response

None