Advanced O&M Command Reference

OceanStor 2000, 5000, and 6000 V3 Series V300R006

This document is applicable to OceanStor 2200 V3, 2600 V3 Video Surveillance Edition, 2600 V3, 5300 V3, 5500 V3, 5600 V3, 5800 V3, and 6800 V3. Based on the CLI, this document describes how to use various commands classified by functionsand how to set the CLI and manage the storage system through these commands. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
cache.sh

cache.sh

Function

The cache.sh command is used to run commands related to the Cache module.

Format

cache.sh { -h | -a | showcoffer | clearcoffer | showdirtydata}

Parameters

Parameter

Description

Value

-h

Displays the help information.

-

-a

Displays functions of each subcommand of the Cache module.

-

showcoffer

Displays status of the coffer.

-

clearcoffer

Clears data in the coffer.

-

showdirtydata

Shows cache dirty data distribution.

-

Modes

Minisystem mode

Usage Guidelines

  • cache.sh showcoffer: displays status of the coffer.
  • cache.sh clearcoffer: clears data in the coffer.
  • cache.sh showdirtydata: shows cache dirty data distribution.
NOTE:

When the data is written to the coffer, do not run the "cache.sh clearcoffer" command. Otherwise, coffer data may be lost.

Example

  • Display functions of each subcommand of the Cache module.
    Storage: minisystem> cache.sh -a 
    cache.sh showcoffer                       : show coffer information. 
    cache.sh clearcoffer                      : clear cache coffer. 
    cache.sh showdirtydata                    : show cache dirty data distribution.
  • Display status of the coffer.
    storage: minisystem> cache.sh showcoffer 
    ibc_os_hs:/diagnose>cache show coffer 
    please wait...... 
    coffer local info: 
     state : 0 
     ctrl ID  : 514 
     sys sn : 144680345676153346 
    coffer mirror info: 
     state : 0 
     ctrl ID  : 514 
     sys sn : 144680345676153346 
    data time: No data in coffer or got coffer state error.
  • Clear data in the coffer.
    Storage: minisystem> cache.sh clearcoffer 
    admin:/diagnose>cache clear coffer 
    please wait...... 
    clean coffer success.
  • Show cache dirty data distribution.
     Storage: minisystem> cache.sh showdirtydata 
    admin:/diagnose>cache show obj v cnt wc 
    Total obj num(44):  
                                   ----io cnt----  -------------page cnt---------------- ---pageunit cnt---  ------chunk cnt------------------  --quota cnt-- --timepoint cnt-- 
     volumeid            volType io mirrorCnt  clean dirty parity faultdirty  readpu writepu read     write     fault dsging dirty         cnt          
     --------            ------- -- ---------  ----- ----- ------ ----------  ------ ------     ----     -----     ----- -----     -----         ---          
     0x0                 thick     16 0          420109 7654     0         0           26790 570        6698     143       0        143       7654          1     
     0x1                 thick     0 0          1410     7788     0         0           589      507        158      144       0        0         7788          1     
     0x2                 thick     16   0          484394 4009     0         0           30568 333        7643     84        0        84        4009          1     
     0x3                 thick     0 0          4100     3688     0         0           501      249        138      84        0        0         3688          1     
     0x4                 thick     16 0          409828 15112 0         0           26601 997        6651     250       0        250       15112         1     
     0x5                 thick     0 0          1372     6258     0         0           489      407        131      112       0        0         6258          1     
     0x6                 thick     16 0          438038 3953     0         0           27671 303        6918     76        0        76        3953          1     
     0x7                 thick     0 0          5138     8296     0         0           847      530        223      152       0        0         8296          1     
     0x8                 thick     16 0          456841 6427   0         0           29002 458        7251     115       0        115       6427          1     
     0x9                 thick     0 0          3523     9664     0         0           831      617        215      163       0        0         9664       1     
    Find Volume cache base num(10):  
    admin:/diagnose>exit 
    admin:/diagnose>cache show obj s cnt wc 
    Total obj num(44):  
                                   ----io cnt----  -------------page cnt---------------- ---pageunit cnt---  ------chunk cnt------------------  --quota cnt-- --timepoint cnt-- 
     volumeid            volType io mirrorCnt  clean dirty parity faultdirty  readpu writepu read     write     fault dsging dirty         cnt          
     --------            ------- -- ---------  ----- ----- ------ ----------  ------ ------     ----     -----     ----- -----     -----         ---          
     0x0                 thick     33 42         4608     17337 1888      0           1575     1619       202      166       0        59        17337         0     
     0x1                 thick     0 0          896      331780 0         0           20803 25943      2605     2598      0        0         331780        0     
     0x2                 thick     44 61         2432     13933 2624      0           1265     1401       163      144       0        82        13933         0     
     0x3                 thick     0 0          1536     137878 0         0           8725     10793      1094     1082      0      0         137878        0     
     0x4                 thick     74 155        6528     5411     1088      0           1662     1576       212      161       0        34        5411          0     
     0x5                 thick     0 0          3200   126686 32        0           8129     9921       1021     996       0        0         126686        0     
     0x6                 thick     41 57         3712     10936 1728      0           1112     1110       144      115       0        54        10936         0     
     0x7                 thick     0 0          256      357104 4576      0           22344 27916      2796     2794      0        0         357104        0     
     0x8                 thick     62 120        2176     9177     1056      0           1325     1497       171      154       0        33        9177          0     
     0x9                 thick     0 0          128      285671 3616      0           17872 22340      2239     2238      0        0         285671        0     
     0x1000000100000000  pool_meta 0 0          76118 96       0         0           4777     11         4777     11        0        3         96            0     
     0x1000000300000002  pool_meta 0 0          8200     96       0         0           519      6          65       1         0        0         96            0     
     0x1000000300000103  pool_meta 0 0          8160     40       0         0           513      3          65       1         0        0         40            0     
     0x100000030000000e  pool_meta 0 0          256      1        0         0           17       1          3        1         0        0         1             0     
     0x100000030000010f  pool_meta 0 0          256      1        0         0           17       1          3        1         0        0         1             0     
    Find Stripe cache base num(15):

System Response

The following table describes the parameter meanings.

Parameter

Meaning

state

Coffer status.

ctrl ID

ID of a controller.

sys sn

System serial number.

data time

Time when data is written into the coffer.

volumeid

Volume ID.

volType

Volume type.

io

Count of cache read/write I/Os.

dirty

Dirty page count.

clean

Clean page count.

mirrorCnt

Mirror I/O count.

faultdirty

Faulty dirty page count.

read

Read chunk count.

write

Write chunk count.

dsg

Cache flushing chunk count.

quota cnt

Dirty page quota count.

fault

Faulty chunk count.

writepu

Write pageunit count.

readpu

Read pageunit count.

parity

Parity page count.

Translation
Download
Updated: 2019-07-12

Document ID: EDOC1000138402

Views: 611910

Downloads: 695

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next