Advanced O&M Command Reference

OceanStor 2000, 5000, and 6000 V3 Series V300R006

This document is applicable to OceanStor 2200 V3, 2600 V3 Video Surveillance Edition, 2600 V3, 5300 V3, 5500 V3, 5600 V3, 5800 V3, and 6800 V3. Based on the CLI, this document describes how to use various commands classified by functions and how to set the CLI and manage the storage system through these commands. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
change fs_alias refresh

change fs_alias refresh

Function

The change fs_alias refresh command is used to forcibly refresh the alias and SN of a file system.

Format

change fs_alias refresh file_system_id=?

Parameters

Parameter

Description

Value

file_system_id=?

File system ID.

The value ranges from 0 to 65535.

Views

Developer view

Usage Guidelines

Before running this command, check whether the ID of the file system is correct.

OceanStor 2100 V3/6800 V3/2600 V3/5300 V3/5500 V3/5600 V3/5800 V3 storage systems support this command.

Example

Forcibly refresh the alias of the file system whose ID is 0.

developer:/>change fs_alias refresh file_system_id=0 
DANGER: You are about to forcibly refresh the alias and SN of the file system. The mount point of the file system may become invalid. 
Suggestions: Before performing this operation: 
1. Unmount the file system on the host. 
2. Ensure that the file system ID you have selected is correct. 
Have you read danger alert message carefully?(y/n)y 
Are you sure you really want to perform the operation?(y/n)y 
Command executed successfully.