Advanced O&M Command Reference

OceanStor 2000, 5000, and 6000 V3 Series V300R006

This document is applicable to OceanStor 2200 V3, 2600 V3 Video Surveillance Edition, 2600 V3, 5300 V3, 5500 V3, 5600 V3, 5800 V3, and 6800 V3. Based on the CLI, this document describes how to use various commands classified by functions and how to set the CLI and manage the storage system through these commands. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
show scsi timeout_cmd

show scsi timeout_cmd

Function

The show scsi timeout_cmd command is used to query the number of SCSI commands that are not returned by the controller for a long period of time.

Format

show scsi timeout_cmd [ controller=? ]

Parameters

Parameter

Description

Value

controller=?

ID of a controller.

To obtain the value, run the "show controller general" command. In the command output, the value of "Controller" refers to the ID of a controller.

Views

Developer view

Usage Guidelines

Run the "show scsi timeout_cmd" command to check whether all values in the "NotBackNum" column are "0". If any value under the "NotBackNum" column is not "0", some SCSI commands are not returned for a long period of time.The command is directly issued to the current controller by default to query the number of SCSI commands that are not returned. If a specific value is displayed for "Controller", the number of SCSI commands that are not returned by the specified controller is queried and the command output is displayed on the current controller.

Example

  • Query the number of SCSI commands that are not returned by the current controller for a long period of time.
    developer:/>show scsi timeout_cmd 
      
    Name                     Controller ID            Not Back Number 
    ----------------         -------------            --------------- 
    TGT_TIME_OUT_CMD         0A                       16
  • Query the number of SCSI commands that are not returned by the specified controller for a long period of time.
    developer:/>show scsi timeout_cmd controller=0B 
      
    Name                     Controller ID            Not Back Number 
    ----------------         -------------            --------------- 
    TGT_TIME_OUT_CMD         0B                       0

System Response

The following table describes the parameter meanings.

Parameter

Meaning

Name

Name of the queried object.

Controller ID

ID of a controller.

Not Back Number

Number of SCSI commands that are not returned for a long period of time.