This document is applicable to OceanStor 2200 V3, 2600 V3 Video Surveillance Edition, 2600 V3, 5300 V3, 5500 V3, 5600 V3, 5800 V3, and 6800 V3. Based on the CLI, this document describes how to use various commands classified by functions and how to set the CLI and manage the storage system through these commands. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
show port fc_long_dis_perf

show port fc_long_dis_perf

Function

The show port fc_long_dis_perf command is used to query the status of remote transmission optimization function on the FC port.

Format

show port fc_long_dis_perf fc_port_id=?

Parameters

Parameter

Description

Value

fc_port_id=?

ID of a port.

To obtain the value, run "show port general".

Views

Developer view

Usage Guidelines

Before performing the operation, confirm that the FC port supports the remote transmission optimization function.

Example

Query the status of remote transmission optimization function on the FC port whose ID is "CTE0.A.H0". The ID and command output vary with the products.

developer:/>show port fc_long_dis_perf fc_port_id=CTE0.A.H0 
FC Long Distance Performance Optimization Enable:Yes 

System Response

The following table describes the parameter meanings.

Parameter

Meaning

FC Long Distance Performance Optimization Enable

Status of remote transmission optimization function on the FC port.