No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Advanced O&M Command Reference

OceanStor 2000, 5000, and 6000 V3 Series V300R006

This document is applicable to OceanStor 2200 V3, 2600 V3 Video Surveillance Edition, 2600 V3, 5300 V3, 5500 V3, 5600 V3, 5800 V3, and 6800 V3. Based on the CLI, this document describes how to use various commands classified by functions and how to set the CLI and manage the storage system through these commands. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
swap dr_star_member remote_replication

swap dr_star_member remote_replication

Function

The swap dr_star_member remote_replication command is used to switch over a remote replication member of a DR Star trio.

Format

swap dr_star_member remote_replication dr_star_id=? remote_replication_id=? member_type=? expected_status=?

Parameters

Parameter

Description

Value

dr_star_id

ID of a DR Star trio.

To obtain the value, run "show dr_star general".

expected_status

Expected status for a remote replication member to switch.

The value can be "standby" or "normal".

member_type

Member type of a DR Star trio.

The value can be "pair" or "consistency_group".

remote_replication_id

ID of a remote replication member that you want to switch over.

To obtain the value, run "show remote_replication general".

Views

Developer view

Usage Guidelines

  • Run this command under the guidance of R&D engineers. This command is only used in abnormal scenarios where two members in a DR Star trio are both in the standby or active state.
  • This operation will change the status of the asynchronous remote replication member of a DR Star trio from the standby state to the active state or from the active state to the standby state.

Example

Switch over remote replication member "200bc71faab10000" of DR Star trio "200bc79b99520000".

developer:/>swap dr_star_member remote_replication dr_star_id=200bc79b99520000 remote_replication_id=200bc71faab10000 member_type=pair expected_status=standby 
DANGER: You are about to forcibly change the status of the asynchronous remote replication member of a DR Star trio from the standby state to the active state or from the active state to the standby state. 
Suggestion: Before performing this operation, contact technical support engineers. 
Have you read danger alert message carefully?(y/n)y 

Are you sure you really want to perform the operation?(y/n)y 
Command executed successfully.

System Response

None