This document is applicable to OceanStor 2200 V3, 2600 V3 Video Surveillance Edition, 2600 V3, 5300 V3, 5500 V3, 5600 V3, 5800 V3, 6800 V3, 18500 V3, and 18800 V3. This document provides error codes of the storage system and guides maintenance engineers and technical support engineers to locate and rectify faults based on error codes. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
0x4000C90F

0x4000C90F

Error Code

Description

Possible Causes

Handling Suggestion

Applicable Model

0x4000C90F

When the storage system is being powered on, the coffer disks (hard disks in slots 0 to 3 of a controller enclosure) had been used by another controller enclosure, are faulty, or are not inserted.

When the storage system is being powered on, the coffer disks had been used by another controller enclosure, are faulty, or are not inserted.

1.Check whether coffer disks are inserted. If yes, go to Step 2. If no, insert coffer disks properly and reset all controllers that failed to be powered on (by running the rebootsys command in the CLI minisystem mode of each controller and then pressing Enter). If the fault persists after the system is restarted, go to Step 2.

2.Collect system logs (Method 1: Download logs on the OceanStor DeviceManager. Method 2: In the CLI minisystem mode of the controllers that fail to be powered on, execute the os_backup_info.sh script. Obtain the logs from the given directory after the log collection is complete. For details, see descriptions about one-click log collection in the user manual.) and contact technical support engineers.

Applicable to all models.