No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Administrator Guide

OceanStor V3 Series V300R006

This document is applicable to OceanStor 2200 V3, 2600 V3, 5300 V3, 5500 V3, 5600 V3, 5800 V3, 6800 V3, 18500 V3, and 18800 V3. Routine maintenance activities are the most common activities for the storage device, including powering on or off the storage device, managing users, modifying basic parameters of the storage device, and managing hardware components. This document is intended for the system administrators who are responsible for carrying out routine maintenance activities, monitoring the storage device, and rectifying common device faults.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Managing Alarms and Events

Managing Alarms and Events

To better manage and handle alarms and events, read this chapter to learn the alarming mechanism, alarm and event notification methods, and alarm dump function.

NOTE:

The event notification function is supported by V300R006C50 and later.

An alarm severity indicates the impact of an alarm on user services. Table 5-13 describes the four severity levels.

Table 5-13 Alarm severity levels

Alarm Severity

Icon

Definition

Way of Handling

Critical

Interrupts services or causes the system to break down.

Must be cleared immediately. Otherwise, the system may break down.

Major

Affects part of the device in a limited range or impacts the system performance.

Must be cleared as soon as possible. Otherwise, important functions will be affected.

Warning

Has no impact on the device. The system detects a potential or imminent fault that may affect services.

A warning is reported to instruct maintenance personnel to promptly find the alarm cause and rectify the potential fault.

Info

Information about operations without any effect on the device.

Lets maintenance personnel know the running status of the network and devices. They are handled based on the actual condition.