Basic Storage Service Configuration Guide for File

OceanStor V3 Series V300R006

This document is applicable to OceanStor 2200 V3, 2600 V3, 5300 V3, 5500 V3, 5600 V3, 5800 V3, 6800 V3, 18500 V3, and 18800 V3. It describes the basic storage services and explains how to configure and manage them.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Check Before Configuration

Check Before Configuration

Check the software installation and initial configuration to ensure that site requirements are met.

Checking Licenses

Log in to DeviceManager. Check whether licenses have been imported and contain the same basic or value-added features as you purchased.

  • If licenses are not imported, import them by following instructions in "Initializing the Storage System" in the installation guide specific to your product model.
  • If the licenses are different from those you purchased, contact Huawei technical support.

Checking Network Connection Status

Table 3-1 lists the check items and describes the check methods.

Table 3-1 Network connection status checklist

Category

Check Item

Check Method

Connection between a maintenance terminal and a storage system

Check whether the management network port on the storage system communicates with the maintenance terminal properly.

In CLI mode of the maintenance terminal, run the following command:

  • For IPv4, ping ip (where ip indicates the IP address of the management network port).
  • For IPv6, ping6 ip (where ip indicates the IP address of the management network port).

If the maintenance terminal receives data packets from the management network port, the storage system and maintenance terminal communicate properly. If the maintenance terminal receives no data packets from the management network port, verify that the physical link is up and the IP address is correctly configured.

Connection between a storage system and an application server (using a Windows application server as an example)

Check whether the front-end port communicates with the service network port on the application server properly.

On the CLI of the application server, run the following command:

  • For IPv4, ping ip (where ip indicates the IP address of the iSCSI front-end port).
  • For IPv6, ping6 ip (where ip indicates the IP address of the iSCSI front-end port).

If the application server receives data packets from the front-end port, the storage system and application server communicate properly. If the application server receives no data packets from the front-end port, replace the network cable or change the IP address of the front-end port, and try again.

Checking Compatibility

Verify that clients' operating systems are compatible with the storage system. You can query the compatibility using the Huawei Storage Interoperability Navigator.