No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Event Reference

OceanStor Dorado V3 Series V300R001

This document is applicable to OceanStor Dorado5000 V3, Dorado6000 V3 and Dorado18000 V3. This document describes the basic knowledge about the events of storage system in terms of event definition, event level, impact on the system, possible cause, and handling procedure. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
0x100F000A009F Failed To Update A Self-Encrypting Disk Key

0x100F000A009F Failed To Update A Self-Encrypting Disk Key

Description

Failed to update a self-encrypting disk key.

Applicable Model

Applicable to all models.

Attribute

ID

Event Level

Automatically Cleared

0x100F000A009F

Major

Yes

Impact on the System

The key may expire, and data on the self-encrypting disk is facing security risks.

Possible Causes

  • The link between storage array and the key management server is down.
  • Key management center certificate of the storage array is unavailable.
  • A system error occurs.

Procedure

  1. Check whether the link between the storage array and the key management server is up.

    1. If yes=> Step2.
    2. If no, recover the link. If the fault persists=> Step2.

  2. Check whether the key management center certificate of the storage array is available.

    1. If yes=> Step3.
    2. If no, import the certificate. If the fault persists=> 3

  3. Collect related information and contact technical support engineers.
Translation
Download
Updated: 2018-10-19

Document ID: EDOC1000141827

Views: 84825

Downloads: 168

Average rating:
This Document Applies to these Products
Related Version
Related Documents
Share
Previous Next