0x100F000A0103 Failed To Enable The Encryption Function Of A Self-Encrypting Disk
Description
Failed to enable the encryption function of a self-encrypting disk.
Applicable Model
Applicable to all models.
Attribute
ID |
Event Level |
Automatically Cleared |
---|---|---|
0x100F000A0103 |
Major |
Yes |
Impact on the System
The self-encrypting disk cannot be added into a disk domain.
Possible Causes
- The link between storage array and the key management server is down.
- Key management center certificate of the storage array is unavailable.
- A system error occurs.
Procedure
- Check whether the link between the storage array and the key management server is up.
- Check whether the key management center certificate of the storage array is available.
- If yes=> Step3.
- If no, import the certificate. If the fault persists=> Step3.
- Collect related information and contact technical support engineers.