Event Reference

OceanStor Dorado V3 Series V300R001

This document is applicable to OceanStor Dorado5000 V3, Dorado6000 V3 and Dorado18000 V3. This document describes the basic knowledge about the events of storage system in terms of event definition, event level, impact on the system, possible cause, and handling procedure. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
0xF00060009 ETH/FCoE Port Link Down

0xF00060009 ETH/FCoE Port Link Down

Description

A ETH/FCoE port is disconnected from the application server or other devices.

Applicable Model

Applicable to all models.

Attribute

ID

Event Level

Automatically Cleared

0xF00060009

Major

Yes

Impact on the System

The application server or other devices cannot communicate with the storage system through the port.

Possible Causes

  • Cables are removed or damaged.
  • The optical module of the port or its peer port is faulty.
  • The port or its peer port is faulty.
  • The interface module where the port or its peer port resides is faulty.
  • The topology modes of the port and its peer port mismatch.
  • The rates of the port and its peer port mismatch.

Procedure

  1. Check cables.

    1. If any cable is removed, reinsert it. If the alarm persists=> 1.2.
    2. If any cable is damaged, replace it. If the alarm persists=> 1.3.
    3. If the port has an optical module=> Step2. If no=> 1.4.
    4. If no exceptions are detected=> Step3.

  2. Check whether optical modules of the port and its peer port are damaged.

    1. Remove the optical module of the port first and then that of its peer port. Reinsert the cables. If the alarm persists=> 2.2.
    2. Replace the optical module of the port first and then that of its peer port. Reinsert the cables. If the alarm persists=> Step3.

  3. Check the port configuration.

    1. Check whether the topology mode of the port matches that of its peer port. If no, make adaptation adjustment. If the alarm persists=> 3.2.
    2. Check whether the rate of the port matches that of its peer port. If no, make adaptation adjustment. If the alarm persists=> Step4.

  4. Check whether the ports and interface modules connected by cables are faulty. If yes, rectify the faults. If the alarm persists=> Step5.
  5. Contact technical support engineers.