This document is applicable to OceanStor Dorado5000 V3, Dorado6000 V3 and Dorado18000 V3. This document describes the basic knowledge about the events of storage system in terms of event definition, event level, impact on the system, possible cause, and handling procedure. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
0xF000B0060 ISCSI Link Of Heterogeneous Array Disconnected

0xF000B0060 ISCSI Link Of Heterogeneous Array Disconnected

Description

The iSCSI link of a heterogeneous storage array is interrupted.

Applicable Model

Applicable to all models.

Attribute

ID

Event Level

Automatically Cleared

0xF000B0060

Major

Yes

Impact on the System

The external LUN may have one link only, or go offline.

Possible Causes

  • The cable is not connected or is damaged.
  • The optical module or interface module is faulty.
  • The switch port is faulty, powered off, or its configurations are incorrect.
  • The heterogeneous array is faulty or is powered off.

Procedure

  1. Check the cable connection.

    1. If the cable is not connected, reinsert the cable. If the alarm persists=> 1.2.
    2. Replace the cable. If the alarm persists=> Step2.

  2. Check whether alarms on the optical module or interface module are generated. If yes, handle the alarm with recommended actions. If the alarm persists=> Step3.
  3. Check the switch status and configurations. If the switch is faulty, is powered off, or has incorrect configurations, recover the problem. If the alarm persists=> Step4.
  4. Check the status of the heterogeneous array. If the heterogeneous array has faults or is powered off, recover the problem. If the alarm persists=> Step5.
  5. Collect related information and contact technical support engineers.