OceanStor Dorado V3 Series V300R001

This document is applicable to OceanStor Dorado5000 V3, Dorado6000 V3 and Dorado18000 V3. This document describes the basic knowledge about the events of storage system in terms of event definition, event level, impact on the system, possible cause, and handling procedure. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
0xF000B0109 Number Of The Connected Remote Arrays Has Exceeded The Upper Limit

0xF000B0109 Number Of The Connected Remote Arrays Has Exceeded The Upper Limit

Description

The number of connected remote storage arrays has exceeded the upper limit.

Applicable Model

Applicable to all models.

Attribute

ID

Event Level

Automatically Cleared

0xF000B0109

Warning

No

Impact on the System

  • New remote storage arrays fail to be connected.
  • If the local storage array is restarted or powered off and on, the connected remote storage arrays may fail to connect to the local storage array again.

Possible Causes

The number of remote storage arrays connected to the local storage array has exceeded the upper limit.

Procedure

  1. Check the network connections between the local and remote storage arrays and disconnect those unnecessary connections.
  2. Modify the configuration of the switch to isolate the switch from the local storage array.