This document is applicable to OceanStor Dorado5000 V3, Dorado6000 V3 and Dorado18000 V3. This document describes the basic knowledge about the events of storage system in terms of event definition, event level, impact on the system, possible cause, and handling procedure. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
0xF000B010B Failed To Register Paths From The Local Storage Array To Heterogeneous Storage Array

0xF000B010B Failed To Register Paths From The Local Storage Array To Heterogeneous Storage Array

Description

Registering paths from the local storage array to heterogeneous storage array fails.

Applicable Model

Applicable to all models.

Attribute

ID

Event Level

Automatically Cleared

0xF000B010B

Warning

No

Impact on the System

The services will be interrupted.

Possible Causes

The external LUN status is abnormal or heterogeneous links are unavailable.

Procedure

  1. Scan the remote LUN to check whether any path registration fails.

    1. Run the scan remote_lun command to trigger the registration of the remote LUN path.
    2. Run the show remote_lun path_status command to check whether there is a Registration failed message in the Path Priority column.
    3. If no, manually clear the alarm.
    4. If yes=> Step2.

  2. Collect related information and contact technical support engineers.