No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Event Reference

OceanStor Dorado V3 Series V300R001

This document is applicable to OceanStor Dorado5000 V3, Dorado6000 V3 and Dorado18000 V3. This document describes the basic knowledge about the events of storage system in terms of event definition, event level, impact on the system, possible cause, and handling procedure. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
0xF0015001B Link Between A Host And Storage Array Is Unstable

0xF0015001B Link Between A Host And Storage Array Is Unstable

Description

A link between a host and storage array is unstable.

Applicable Model

Applicable to all models.

Attribute

ID

Event Level

Automatically Cleared

0xF0015001B

Major

Yes

Impact on the System

The storage array reliability decreases, causing service interruption risks.

Possible Causes

  • Cables between the host and the storage array are loose or damaged.
  • Optical modules are faulty.
  • The host port is faulty.
  • The host HBA is faulty.
  • Switches are faulty.

Procedure

  1. Check the cables connected between the host and the storage array.

    1. If any cable is loose, reinsert it. If the alarm persists=> 1.2.
    2. Replace the cable. If the alarm persists=> Step2.

  2. Check whether alarms are generated indicating optical module faults.

    1. If yes, handle the alarms by taking recommended actions. If the alarm persists=> Step3.
    2. If no=> Step3.

  3. Check whether alarms are generated indicating port faults.

    1. If yes, handle the alarms by taking recommended actions. If the alarm persists=> Step4.
    2. If no=> Step4.

  4. Check the HBAs on the host. Contact the HBA provider for help when necessary.
  5. Check related switches. Contact the switch provider for help when necessary.
  6. Collect related information and contact technical support engineers.