0xF00170014 Power Module Has No Input
Description
There is no power input to a power module.
Applicable Model
Applicable to all models.
Attribute
ID |
Event Level |
Automatically Cleared |
---|---|---|
0xF00170014 |
Major |
Yes |
Impact on the System
The storage system fails to start.
Possible Causes
- Power cables are removed or damaged.
- No external power is input.
- The power module is faulty.
Procedure
- Check whether power cables are connected correctly.
- Check power cables.
- If any power cable is removed, reinsert it. If the alarm persists=> 2.2.
- Replace the power cable. If the alarm persists=> Step3.
- Check whether the power module is inserted.
- If yes=> Step4.
- If no, reinsert the power module. If the alarm persists=> Step4.
- Check whether any external power is input to the power module.
- If yes=> Step5.
- If no, supply power to the storage system correctly. If the alarm persists=> Step5.
- Replace the power module. If the alarm persists=> Step6.
- Collect related information and contact technical support engineers.