Event Reference

OceanStor Dorado V3 Series V300R001

This document is applicable to OceanStor Dorado5000 V3, Dorado6000 V3 and Dorado18000 V3. This document describes the basic knowledge about the events of storage system in terms of event definition, event level, impact on the system, possible cause, and handling procedure. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
0xF00CE002A Disk Enclosure Is Working In Single Link State

0xF00CE002A Disk Enclosure Is Working In Single Link State

Description

A disk enclosure is working in single-link state.

Applicable Model

Applicable to all models.

Attribute

ID

Event Level

Automatically Cleared

0xF00CE002A

Major

Yes

Impact on the System

A disk enclosure working in single-link state may go offline.

Possible Causes

  • Expansion cables are incorrectly connected or removed.
  • Expansion modules are incorrectly inserted or removed.
  • Expansion cables are damaged.
  • Expansion modules are faulty.

Procedure

  1. Check the expansion module and expansion cable.

    1. If the expansion module or expansion cable is removed, reinsert the expansion cable or expansion module. If the alarm persists=> 1.2.
    2. Replace the expansion cable. If the alarm persists=> 1.3.
    3. Replace the expansion module. If the alarm persists=> Step2.

  2. Collect related information and contact technical support engineers.
Translation
Download
Updated: 2018-10-19

Document ID: EDOC1000141827

Views: 96049

Downloads: 181

Average rating:
This Document Applies to these Products

Related Version

Related Documents

Share